EN
52
leakage with your hands, other parts of
your body, or rags.
10. If there is no leakage put the switch (1) in
the off position, point the spray gun down
in an empty container, release the trigger
lock and press the trigger to empty the
fluid from the system.
11. Apply the trigger lock and turn the
pressure relief valve lever (6) to its
vertical position.
PREPARATION OF MATERIAL
The material to be sprayed must be mixed,
diluted (if applicable) and filtered before use.
If diluting is necessary use a solvent with a flash
point higher than 21°C (flammable liquid class
2a or higher) that is compatible with actual
material. Read all the safety instructions, other
instructions and safety information sheets
and labels on the containers for paints and
solvents. Follow the instructions from the
manufacturer of the paint and solvent.
FILTERING
Disposable filter bags can be bought in paint
shops and used to remove coarse particles and
impurities from new or used material. Filter
the material before spraying to avoid filling
problems and blocking the nozzle insert. Put a
disposable filter bag over a clean container and
let the material run through the filter.
PREPARATIONS FOR SPRAYING
When the material has been prepared and
filtered it is ready to be sprayed.
1. Check that all the connections are firmly
tightened, that the pressure relief valve
lever (6) is in its vertical position, and that
the trigger lock is applied.
2. Put the end of the suction hose (10) in
the material container so that the suction
USE
FLUSHING OF PRESERVATIVE FLUID
NOTE:
The product must be flushed/tested before
use. The product is tested at the factory with
a fluid that must flushed out of the system
before it is used for the first time.
The preservative lubricant must then be
flushed out from the system before use.
1. Check that the power switch (1) is
switched off.
2. Put the end of the outlet hose (11) in a
suitable container and put the end of the
suction hose (10) in an earthed metal
container, partly filled with cleaning fluid,
to flush the fluid from the factory out of the
product. Flush out water-based paint with
water and oil-based paint and preservative
with white spirit or the equivalent.
3. The pressure relief valve lever (6) must be
in its vertical position.
4. The plug (9) must only be connected to a
correctly earthed power point.
5. Press the manual valve (4) several times
to release the inlet valve ball.
6. Turn the pressure control knob (8) to the
lowest setting.
7. Put the switch (1) in the on position. The
product pump starts and fluid flows in
through the suction hose (10) and out
through the outlet hose (11).
8. Let the fluid flow out through the outlet
hose (11) for 45 to 60 seconds and then
turn back the pressure relief valve lever (6)
to its horizontal position. Wait until the
pump stops.
9. Wait about 1 minute and then check that
all the connections are tight. If there is
any leakage, release the pressure and
tighten all the connections and then
repeat steps 1 to 8. Never attempt to stop
Summary of Contents for 011485
Page 4: ...1 12 13 1 11 9 8 10 7 2 6 4 5 3 ...
Page 5: ...2 5 4 3 ...
Page 6: ...6 7 1 2 3 4 5 ...
Page 7: ...8 9 1 2 3 4 5 6 7 8 ...
Page 8: ...10 ...