EN
38
10.
Repeating the above steps until the log has been split to the required size.
11.
Turn off the log splitter and disconnect it from the mains supply when finished.
MAINTENANCE
Replacing the hydraulic fluid
Replace the hydraulic fluid after approximately 150 hours of operation.
1.
Turn off the log splitter and disconnect it from the mains supply.
2.
Unscrew and remove the drain plug.
3.
Place a suitable container, which holds about 3 litres, under the drain hole.
4.
Carefully tip the log splitter and allow all the hydraulic fluid to flow into the container. Make
sure not to spill any hydraulic fluid onto the ground.
5.
Position the log splitter vertically on the motor end and fill with fresh hydraulic fluid.
6.
Only fill with hydraulic fluid of the intended type and with the correct viscosity.
NOTE:
Used
hydraulic fluid must be recycled in accordance with local regulations.
Maintenance and storage
• Always disconnect the log splitter from the mains supply before working on the splitting wedge.
• Brush off the chip and the like from the log splitter after use.
• When not in use, store the log splitter in a dry place out of the reach of children.
Transport
• The log splitter can be transported in the boot of a car.
• Use the transport handle for short distances.
NOTE:
• Never lift or carry the log splitter while running.
• Exercise care when moving the log splitter on uneven or unstable surfaces.
• Make sure that the log splitter does not tilt, tip over or drop down.
• Never allow anyone to sit on the log splitter when moving it.