8
Clean Pin Alert LED and Output
Red flashing LED shows that bar is dirty and needs cleaning. Solid red illumination
indicates a fault with the high voltage output.
No light - OK
Red flashing - Cleaning required
Red constant - Fault
The signal is an open collector output. Open circuit when the system is OK (Flashing
green LED). Grounded when the Clean Pin alert is active (Flashing red LED) or
System fault (Solid red LED).
The output signal is a constant signal irrespective of whether the LED is flashing red
or constantly red. In either case, the signal alerts the operator to inspect the bar to
discover what has caused the alert.
External
Alarm/Lamp/Relay
24
V Max
Output
External
Alarm/Lamp/Relay
Output
20m
A Max
Output OFF (= Green LED Flashing)
Output ON (= Red LED Flashing or Solid)
Open Collector Alarm output