14
Connection using Meech 24VDC power supply
Meech 24VDC supplies are grounded internally. It is important that the mains
connection offers a ground connection. Two-pin outlets without a ground connection
must not be used, unless the ground post on the 971IPS bar is connected to ground.
The switchmode power supply has a standard IEC C13 mains socket and a 2000mm
HT cable to M8 Connector. A break-out wire from the switchmode power supply
provides the Clean Pin Alert output signal.
Connection using customer’s own power supply:
It is the customer’s responsibility to check that either the 24V power supply they will
be using is grounded. If it is NOT grounded they must check that grounding it via the
ground post on the 971IPS bar will not affect any other systems running from that
power source.
The 24V supply should be protected with a 1 Amp fuse.
Summary of Contents for Hyperion 971IPS
Page 1: ...1 Hyperion 971IPS Operating Manual Long Range DC Bar...
Page 2: ......
Page 4: ......
Page 21: ...19 Health and Safety Emission of Ozone Considerably below international standard of 0 1ppm...
Page 22: ...20...