5-1
MPT12 Manual
24 May 2017
SECTION 5
Maintenance and Repair
Contents
DESCRIPTION
This section discusses inspection, maintenance, and
repair of the MPT. Failure to perform regular
inspections on your MPT system may result in
damage to the components and reduced life-span of
the MPT. If your system is not covered in this manual
or you are having difficulties with the installation
please contact The MEGA Corp. Product Support
Group at: U.S. Toll Free 1-800-345-8889 or Direct 1-
505-345-2661 or visit our website at
www.megacorpinc.com for more contact
information.
WATER TANK
The MPT tank is 2.59m (8.5 ft) in diameter, 11.13m
(36.5 ft.) in length, and has a capacity of 45.42 L
(12,000 gallons). The corners of the tank are
reinforced to provide sturdy connection to supports.
An access ladder leading to the top of the tank is
located at the rear of the trailer, and a ladder is
located inside of the tank. An 8” diameter float is
located inside of the tank for automatic fill shut-off
when the tank is full.
INSPECTION
1. Inspect tank exterior paint for wear and
corrosion.
2. Inspect tank outer skins for damage or leaks.
3. Inspect tank outer structure for damage.
4. (Interior coating equipped only) Inspect tank
interior coating for wear, condition and
deterioration. Repair as required.
5. Inspect all water ways, pipes, and couplings for
security, wear and leaks.
6. Inspect all tank mounted wiring, and hydraulic
hoses for wear, security and leaks.
REPAIR
Paint
Remove corrosion. Prime and paint.
Interior Coating (Epoxy or Urethane)
1. Brief and follow all local confined space entry
requirements and procedures.
Do not enter confined spaces without following
established site specific procedures. Failure to
follow proper safety procedures will result in
serious injury or death.
2. Use all required safety equipment and
procedures to perform grinding and painting of
interior coatings. Refer to coating manufactures
MSDS information.
3. Inspect coating for flaking, bubbling or cracking.
4. Remove damaged coating via wire brush wheel
or grinder. Ensure coating is removed about 1-2”
beyond the visible crack.
5. Wipe area clean and inspect exposed edges of
the coating. Ensure exposed edges of the coating
still adhere to the metal surface.
6. Wipe clean with Prep Sol or equivalent
preparation solution to remove debris and/or oil.
Description .........................................................................5-1
Water Tank ..........................................................................5-1
Float Adjustment..............................................................5-2
Summary of Contents for MPT12
Page 3: ...MPT12 Manual 24 May 2017 TABLE OF CONTENTS B Blank ...
Page 13: ...MPT12 Manual 24 May 2017 SECTION 2 System Description 2 6 Blank ...
Page 15: ...MPT12 Manual 24 May 2017 SECTION 3 Commissioning 3 2 Blank ...
Page 20: ...MPT12 Manual 24 May 2017 SECTION 4 Operation Instructions 4 5 Figure 4 1 Tie downs ...
Page 21: ...MPT12 Manual 24 May 2017 SECTION 4 Operation Instructions 4 6 Blank ...
Page 37: ...MPT12 Manual 24 May 2017 SECTION 8 Illustrated Parts Breakdown 8 6 Blank ...
Page 39: ...MPT12 Manual 24 May 2017 SECTION 9 Appendix Installation Drawings 9 B Blank ...
Page 44: ...Appendix A MPT12 A 5 ...
Page 46: ...Appendix A MPT12 A 7 ...
Page 47: ... IF EQUIPPED Appendix A MPT12 A 8 ...
Page 48: ...Appendix A MPT12 A 9 ...
Page 49: ...Appendix A MPT12 A 10 ...
Page 66: ...Appendix A MPT12 A 27 ...