CAUTION
DO NOT use a sharp implement as damage to the element surface could be
caused.
●
Ensure sealing surfaces are clean and seals are undamaged, if in doubt fit a
new
gasket. (spare part number 95611025)
●
Replace immersion heater(s) and make
sure the 8 nuts are correctly torqued (20Nm or
14.75 ft/lbf)
●
Rewire, check, close and secure immersion heater housing
cover(s).
Expansion vessel charge pressure
●
Remove the dust cap on top of the vessel.
accordance with the inlet pressure set on the pressure reducing valve.
●
If it is
lower than the required setting it should be re-charged using a tyre pump
(Schrader valve type).
CAUTION
DO NOT OVER-CHARGE
●
Re-check the pressure and when correct replace the dust cap.
page 25
Re-commissioning
●
Check all electrical and plumbing connections are secure. Close the drain
cock.
●
With a hot tap open, turn on the cold water supply and allow unit to
refill.