Spare Parts
A full range of spare parts are available for the cylinder range (table 8). Refer to
the technical data label on the unit to identify the model installed and ensure the
correct part is ordered. You
Fault Possible Cause Remedy
No hot water
flow
Mains supply off Check and open stop cock Strainer blocked Turn off water
supply. Remove strainer and clean
Cold water combination valve incorrectly fitted Check and refit as required
Water from hot tap is cold Direct immersion heater not switched on Check
and switch on
Direct immersion heater thermal cut-out has operated Check, reset by pushing
button on thermostat
Indirect programmer set to central heating only Check, set to domestic hot water
programme
Indirect boiler not working Check boiler operation.
If fault is suspected consult boiler manufacturer's instructions
Indirect thermal cut-out has operated Check, reset by pushing button on
thermostat.
Check operation of indirect thermostat
Indirect motorised valve not connected correctly Check wiring and/or plumbing
connections to motorised valve
Water discharges
from expansion valve Intermittently