COMMISSIONING
35
Commissioning record
38
© Baxi Heating UK 2012
Commissioning record
The following chart should be completed during Commissioning of the system.
Installer:
_______________________________
Contact details:
_______________________________
Original commissioning date: _______________________________
General Commissioning
All pipework correctly installed, identified and
❑
earth bonded
Solar expansion vessel charge pressure checked
❑
r
a
b
m
e
t
s
y
s
e
h
t
g
n
il
li
f
e
r
o
f
e
b
t
e
s
d
n
a
Solar primary system filled with heat transfer
❑
fluid supplied
System pressure test carried out
❑
Air vented from system
❑
Exposed pipework insulated using high-temp and
❑
weather resistant insulation (bird/rodent-proof)
collector installation weatherproof
❑
Collector fixings checked and secure
❑
Hydraulic Station
r
a
b
d
l
o
c
n
e
h
w
e
r
u
s
s
e
r
p
m
e
t
s
y
S
n
i
m
/l
d
l
o
c
n
e
h
w
w
o
lf
y
r
a
m
i
r
p
r
a
l
o
S
Isolating/non-return valves (flow and return) in
❑
operating position
Solar Collectors
Collector visually inspected for defects
❑
Collector temperature sensors correctly installed
❑
and secured
Pipe entry points to building weatherproof
❑
Solar Differential
Temperature Controller
Record all operational parameters set
❑
(see separate table)
Pump operation tested in automatic and manual
❑
modes
All cables correctly installed and secured
❑
Suitably fused isolating device installed
❑
Controller earthed
❑
Solar Cylinder
Cylinder installed and commissioned in
❑
accordance with cylinder installation instructions
Adjustable in menu
Typical
Current
"Programming"
adjustment adjustment
*
C
°
5
6
:
1
k
n
a
t
e
g
a
r
o
t
S
Maximum storage temperature
K
7
:
1
k
n
a
t
e
g
a
r
o
t
S
switch-on difference (dTon)
K
3
:
1
k
n
a
t
e
g
a
r
o
t
S
switch-off difference (dToff)
Minimum pump power on
100%
rotational speed regulation
Switch-on temperature of
40°C
thermostat function
Hysteresis of thermostat function
10 K
2nd temperature differential
65°C
controller maximum temperature Tmax
2nd temperature differential controller
7 K
hysteresis dTmax
Adjustable in menu
Typical
Current
"Basic adjustments"
adjustment adjustment
Switching on or off the function
0 = off
*
collector protection
Temperature at which the collector
120°C
*
protection function is active
Switching on or off the function
0 = off
*
recooling (only when the collector
protection is on)
Temperature to which the storage
40°C
*
tank is recooled when collector
protection function is on
Function for time-controlled
0 = off
circulation in operation with
tube collectors
Switching on or off the function
2 = on
energy productivity measurement
Choice of glycol types used
0 = Anro
Mixture ratio of coolants
50%
m
/l
0
1
n
i
m
r
e
p
s
e
r
ti
L
Switching on or off the function
0 = off
antifreezing
Temperature at which the antifreezing
3°C
is active
Alternative choice of the cooling,
2
thermostat function or the 2nd
temperature differential controller
0
e
p
y
t
e
p
y
t
m
e
t
s
y
S
Time control in secs
240
1
y
ti
r
o
i
r
p
e
g
a
r
o
t
S
Solar differential temperature controller - operational parameters
If any factory values are changed please enter the new values in the
table below.
BPEC No.:
_______________________________
Serial Nos. Cylinder _______________________________
Collector _________________
Pump Station Serial Number: ___________________________
*
Megaflo recommends these settings are left at the default value.