M
AINTENANCE
39
Is the mains water
supply turned on?
Is the strainer blocked?
Is the cold water
combination valve correctly
fitted?
No hot water flow
Contact an authorised service
engineer for further advice
Turn on mains water supply
Turn off water supply. Remove and
clean filter (see Fig 33)
Check and refit as required.
Observe direction of flow arrows
NO
YES
NO
YES
NO
YES
Water from hot taps is cold
Contact an authorised service
engineer for further advice
Switch on mains power supply
Check if tripped.
Reset by pressing button
Check auxiliary heat source is
switched on. Controller to provide
heat in event insufficient solar gain
Check.
If tripped reset by pressing button
Check.
Set to a CH programme
Check.
Switch on supply to
immersion heater
Check boiler operation.
If faulty contact boiler manufacturer
Check.
If tripped reset by pressing button
Check wiring and plumbing
connections to motorised valve.
Check operation and replace
if necessary
Is the mains power
supply switched on?
Insufficient solar
gain with no auxiliary
heating on
Boiler working correctly
Has solar thermal
cut-out operated?
Has indirect thermal
cut-out operated?
Indirect
Programmer set to central
heating only
Is motorised valve
working correctly?
Has immersion
heater thermal cut-out
operated?
Direct
Is immersion heater
switched on?
NO
YES
NO
YES
YES
NO
YES
NO
YES
NO
NO
YES
YES
NO
NO
YES
YES
NO
Figure 32 – Fault finding flow diagrams
Summary of Contents for Eco SolaReady
Page 1: ...Hot Water Cylinders MEGAFLO Eco SolaReady Unvented MEGAFLO Eco SolaReady Product Guide...
Page 48: ...SERVICING 48...
Page 50: ...SERVICING 50...
Page 51: ...SERVICING 51 Notes...