PR
ODUC
T SPECIFIC
ATION
6
Water Supply
Bear in mind that the mains water supply to the property will be supplying both the hot and cold water requirements
simultaneously. It is recommended that the maximum water demand be assessed and the water supply checked to ensure this
demand can be met.
NOTE: A high mains water pressure will not always guarantee high flow rates.
Wherever possible the main supply pipe should be in 22mm. The minimum mains water supply requirements should be
0.15 MPa (1.5 bar) working pressure and 20 litres per minute flowrate.
At these values outlet flowrates may be poor if several outlets are used simultaneously, the higher the available pressure and
flowrate the better the system performance will be.
The Megaflo Eco SolaReady has an operating pressure of 3 bar which is controlled by the 3 Bar Pressure Reducing Valve. The
3 Bar Pressure Reducing Valve can be connected to a maximum mains supply pressure of 1.6 MPa (16 bar). The water supply
must be of wholesome water quality (Fluid Category 1 as defined by the Water Supply Regulations 1999).
The Megaflo Eco SolaReady is only to be used for the storage of wholesome water (max. 250mg/l chloride).
Electrical Supply
WARNING: THIS APPLIANCE MUST BE EARTHED. IT IS SUITABLE FOR A.C. SUPPLY ONLY. ELECTRICAL INSTALLATION MUST BE
CARRIED OUT BY A COMPETENT ELECTRICIAN AND BE IN ACCORDANCE WITH THE LATEST I.E.E. WIRING REGULATIONS.
ENSURE THE ELECTRICAL SUPPLY IS SWITCHED OFF BEFORE MAKING ANY CONNECTIONS TO THE MEGAFLO ECO SOLAREADY.
The Environment
This product is made from many recyclable materials, therefore at the end of its useful life it should be disposed of at a Local
Authority Recycling Centre in order to realise the full environmental benefits. Insulation is by means of an approved HCFC/CFC
free polyurethane foam.
Specifications and Dimensions
Outline Specifications
Maximum mains water supply pressure (to Cold Water Combination Valve)
1.6 MPa (16 bar)
Operating pressure (Pressure reducing valve set pressure – non adjustable)
0.3 MPa (3 bar)
Maximum primary circuit pressure
0.3 MPa (3 bar)
Expansion relief valve set pressure
0.8 MPa (8 bar)
Temperature / Pressure Relief Valve set temp / pressure
90ºC / 1MPa (10 bar)
Immersion heater rating (a.c. supply only)
3kW @ 240V, 2.7kW @ 230V
Outer casing:
White polyester coated corrosion resistant steel.
Water container:
Duplex stainless steel. 100% pressure tested to 1.5 MPa (15 bar).
Thermal insulation:
CFC/HCFC free fire retardant expanded polyurethane foam with zero ozone depletion potential. It has a Global Warming
Potential (GWP) of 3.1. Nominal thickness 60mm.
Pipe connections:
All connections accept 22mm outside diameter pipe – compression nuts and olives supplied. Thread rate is ¾" BSP male
parallel to accept standard ¾" BSP female fittings if required.
Safety features:
Solar primary
Manually resettable thermal cutout on electrical supply to solar differential controller
Direct units
Manually resettable thermal cut-out on each heating element
Factory fitted Temperature / Pressure Relief Valve
Indirect units
Manually resettable thermal cut-out on heating element
Manually resettable thermal cut-out for primary heating. Must be wired in conjunction with 2-port motorised valve supplied
Factory fitted Temperature / Pressure relief valve
Summary of Contents for Eco SolaReady
Page 1: ...Hot Water Cylinders MEGAFLO Eco SolaReady Unvented MEGAFLO Eco SolaReady Product Guide...
Page 48: ...SERVICING 48...
Page 50: ...SERVICING 50...
Page 51: ...SERVICING 51 Notes...