background image

Technical Information

 

3

Part Numbers

 

Fixture

 

4460

-

Paramount Pendant Q350

 

Mechanical Specifications

 

Housing:

  

DMX Connectors: 

Power Connections:

 

Metal & Acrylic

 

XLR 5pin In and Out / Screw Terminal for Permanent Installation

 

Panel Mount Neutrik True Power In Connection (Nema 5

-

15 to Neutrik True power male cable included) / 

Screw Terminal for Permanent Installation

Thermal: 

Maximum ambient temperature 104° 

Maximum surface temperature 140°

 

Display

:

 

Digital

 

Secondary Safety:

  

1” 

Eye Bolt

 

Fastening  System: 

Mounting Brace

 

Lens Angle:

 

10°

 

Size:

 

Weight

:

 

43.5lb

 

Electrical Specifications

 

Down LED Type:

 

1 COB LED 200W

 

Color Type:

 

Red, Green, Blue, Warm White

 

Side LED Type:

 

90 SMD LED 1.5W

 

Color Type:

 

Red, Green, Blue, Warm White

 

Segment Control: 

15 Side 1 Down 

 

Wireless DMX:

 

Wireless Solution Receiving 

 

CCT:

 

 

3077K on Warm White

 

Power Consumption: 

Universal 100 

-

 240V 50/60 Hz 

Ballast: 

Electronic

 

Watts: 

358W

 

Amps:

 

2.99A

 

PF:

 

.60

 

Protocol:

  

DMX 512 

 

RDM:

 

Yes

 

DMX Channels: 

5 Modes of Operation

 

Mode 4Channel

 

Red, Green, Blue, Warm White

 

Mode 8Channel 

 

Side Red, Green, Blue, Warm White, Bottom Red, Green, Blue, Warm White 

 

Mode 15 Channel 

 

Dimmer, Side Red, Green, Blue, Warm White, Bottom Red, Green, Blue, Warm White, Shutter Macro, Macro 

Speed, Color Macro, Macro Speed, Side Strobe, Bottom Strobe

 

Mode 64 Channel

 

16X R,B,G,WW 

 

Mode 75 Channel 

 

Dimmer, Side Red, Green, Blue, Warm White, Bottom Red, Green, Blue, Warm White, Shutter Macro, Macro 

Speed, Color Macro, Macro Speed, Side Strobe, Bottom Strobe, 16X R,B,G,WW 

Control & Programming

 

Summary of Contents for PARAMOUNT PENDANT Q350

Page 1: ...mation 2 Specifications 3 Main Power Connection 4 DMX 512 Connection 4 DMX Profile 5 Main Control Menu 11 Size and Weight 13 Rigging the Fixture 14 Cleaning Maintenance 14 Parts List 14 Warranty 15 Cu...

Page 2: ...t not be left on for long periods of time Protection Against Mechanical Hazards 1 Use safety chain when hanging unit 2 Use quality clamps or bolts when positioning unit 3 Do not open unit while it is...

Page 3: ...ite Side LED Type 90 SMD LED 1 5W Color Type Red Green Blue Warm White Segment Control 15 Side 1 Down Wireless DMX Wireless Solution Receiving CCT 3077K on Warm White Power Consumption Universal 100 2...

Page 4: ...Ohm re sistor between the and the signal into a 3 or 5 pin XLR plug and plug it in to the last fixture on the signal run Pre manufactured terminator plugs are available for purchase from your Mega Li...

Page 5: ...escription Value Init 1 Dimmer Dimmer off to full 0 255 255 2 LED Color Red LED Intensity side fixture 0 255 255 3 LED Color Green LED Intensity side fixture 0 255 255 4 LED Color Blue LED Intensity s...

Page 6: ...Speed 0 255 0 No Function 0 1 Program 1 2 12 Program 2 13 23 Program 3 24 34 Program 4 35 45 0 Program 5 46 56 Program 6 57 67 Program 7 68 78 Program 8 79 89 Program 9 90 100 Program 1 101 111 12 Co...

Page 7: ...ED Color White LED Intensity 5 0 255 0 21 LED Color Red LED Intensity 6 0 255 0 22 LED Color Green LED Intensity 6 0 255 0 23 LED Color Blue LED Intensity 6 0 255 0 24 LED Color White LED Intensity 6...

Page 8: ...Paramount Q350 15 Ch Mode DMX Ch Function Description Value Init 1 Dimmer Dimmer off to full 0 255 255 2 LED Color Red LED Intensity side fixture 0 255 255 3 LED Color Green LED Intensity side fixtur...

Page 9: ...peed 0 255 0 No Function 0 1 Program 1 2 12 Program 2 13 23 Program 3 24 34 Program 4 35 45 Program 5 46 56 Program 6 57 67 Program 7 68 78 Program 8 79 89 Program 9 90 100 Program 1 101 111 12 Color...

Page 10: ...0 44 LED Color Red LED Intensity 8 0 255 0 45 LED Color Green LED Intensity 8 0 255 0 46 LED Color Blue LED Intensity 8 0 255 0 47 LED Color White LED Intensity 8 0 255 0 48 LED Color Red LED Intensit...

Page 11: ...ottom Strobe Mode 64 Channel 16X R B G WW Mode 75 Channel Dimmer Side Red Green Blue Warm White Bottom Red Green Blue Warm White Shutter Macro Macro Speed Color Macro Macro Speed Side Strobe Bottom St...

Page 12: ...This Setting allows you to select what function the LEDS will do if DMX signal is lost during use Off will turn all Dimmer chan nels to the 000 position Hold will hold the last DMX command re ceived M...

Page 13: ...12 25 With Decorative Cover Size and Weight Size 41 12 x 12 Packaged Size 45 x 16 5 x 16 5 Weight Net 43 5 lb Gross 50 lb 13 Top View 12 12 41 12 Bottom View...

Page 14: ...e installations must be carried out by an authorized dealer or trained professional 2 Unit may cause severe injures if you have doubts concerning the safety do not install 3 Unit is to be 24inches awa...

Page 15: ...over the course of normal product use Slight deviations in the specified values of intensity and color that do not affect the functionality of the product Use of the product not for its intended purp...

Page 16: ...er any question should you encounter a prob lem Please visit our website for any other related technical documents For service related issue please contact our service dept Monday Friday 9am to 6pm CS...