Although all gas connections on the braai are leak tested at the factory prior to shipment, a complete gas
tightness check must be performed at the installation site due to possible mishandling in shipment, or
excessive pressure unknowingly being applied to the unit. Periodically check the whole system for leaks
following the procedures listed below. If the smell of gas is detected at anytime you should immediately
check the entire system for leaks.
BEFORE TESTING
Make sure that all packing material is removed from the braai including tie-down straps.
DO NOT SMOKE WHILE LEAK TESTING. NEVER PERFORM LEAK TEST WITH AN OPEN FLAME.
Make a soap solution of one part liquid detergent and one part water. You will need a spray bottle, brush, or
rag to apply the solution to the fittings. For the initial leak test, make sure the LP gas cylinder is 80% full.
TO TEST
1.
Make sure the control valves are in the “OFF” position, and turn on the gas supply.
2. Check all connections from the LP gas regulator and supply valve up to and including the connection to
the manifold pipe assembly (the pipe that goes to the burners). Soap bubbles will appear where a leak is
present.
3. Only those parts recommended by the manufacturer should be used on the braai.
4. Substitution will void the warranty. Do not use the braai until all connections have been checked and do
not leak.
GAS FLOW CHECK
Each braai burner is tested and adjusted at the factory prior to shipment; however, variations in the local gas
supply may make it necessary to adjust the burners. The flames of tips, excessive noise or lithe burners
should be visually checked.
Flames should be blue and stable with no yellow. If any of these conditions exist, check to see if the air
shutter or burner ports are blocked by dirt, debris, spider webs, etc. If you have any questions regarding
flame stability, please call customer care.
ALWAYS CHECK FOR LEAKS AFTER EVERY LP GAS CYLINDER CHANGE
CHECK ALL GAS SUPPLY FITTINGS FOR LEAKS BEFORE EACH USE. IT IS HANDY TO KEEP A
SPRAY BOTTLE OF SOAPY WATER NEAR THE SHUT-OFF VALVE OF THE GAS SUPPLY LINE.
SPRAY ALL THE FITTINGS. BUBBLES INDICATE LEAKS.
27
CAUTION
Place dust cap on cylinder valve outlet when the cylinder is not in use. Only install the
type of dust cap on the cylinder valve outlet that is provided with the cylinder valve.
Other types of caps or plugs may result in leaking of LP gas.
The gas must be turned off at the supply cylinder when the unit is not in use.
If the appliance is stored indoors the cylinder must be disconnected and removed from
the appliance. Cylinders must be stored outdoors in a well-ventilated area out of the
reach of children.
LEAK TEST INSTRUCTIONS
Summary of Contents for 720-0804C
Page 9: ...9 PACKAGE PARTS LIST 5 6 7 8 9 10 1 3 4 2 x2 x2 x2 ...
Page 10: ...10 14 16 17 18 19 20 11 12 13 15 x2 x2 x2 PACKAGE PARTS LIST x2 ...
Page 11: ...11 23 24 22 25 x3 x2 21 PACKAGE PARTS LIST ...
Page 13: ...1 2 3 4 5 4 13 1 A x4 2 A x4 ASSEMBLY INSTRUCTIONS ...
Page 14: ...2 7 6 3 8 14 3 4 A x8 ...
Page 15: ...B x4 9 10 11 E x2 D x2 15 5 6 ...
Page 16: ...16 7 8 A x4 12 13 ...
Page 17: ...17 9 10 A x4 A x4 ...
Page 18: ...18 11 12 B x4 15 14 16 14 ...
Page 19: ...19 13 14 C A x3 x3 B x2 Bx2 ...
Page 20: ...20 15 16 B x4 16 17 18 ...
Page 21: ...21 17 18 C A x3 x3 B x2 17 Bx2 ...
Page 22: ...22 19 20 19 20 Bx2 Ex2 B x2 E x2 19 ...
Page 23: ...23 21 22 21 22 ...
Page 24: ...24 23 24 23 24 ...
Page 25: ...25 25 26 25 ...