8.
Parameter's
To move round the menu and to set particular parameters there are four buttons placed on
the driver's panel:
“MODE/ ”
,
“MENU/OK”
,
“+”
,
“-”
. The parameters chosen by the
user are divided into four groups: (A)
“CH FURNACE SETTINGS”
, (B)
“WUW BUFFER
SETTINGS”
, (C)
“BURNER SETTINGS”
, (D)
“DRIVER SETTINGS”
. The division of
particular parameters in groups is shown in the
“Settings' table”.
➢
CH FURNACE SETTINGS
(A)
FUNCTION
NO.
FUNCTION
NAME
SETTING
UNIT
SETTING
RANGE
MANUFACTURER
SETTING
1
HEATING WATER
TEMPERATURE
º
C
35 - 85
65*
2
CH PUMP ACTIVATION
TEMPERATURE
º
C
20 - 60
35*
3
CH FURNACE
HYSTERESIS
º
C
1 - 20
5*
4
FURNACE
MODE
---
Winter/Summer
Winter*
➢
BURNER SETTINGS
(B)
FUNCTION
NO.
FUNCTION
NAME
SETTING
UNIT
SETTING
RANGE
MANUFACTURER
SETTING
1
BURNER POWER
(WORK)
kW
10 - 90
30*
2
BURNER POWER
(MAINTAIN)
kW
2 - 19
10*
3
BURNER
MODE**
---
Continuous/
Single/Analogue
Continuous*
4
MAXIMUM MAINTAIN
TIME
hours
Off – 8
Off *
5
SELF CLEANING FREQ
TIME
min
10 – 480
240*
6
SELF CLEANING
TIME
sec
Off – 60
off
7
BURNER FLAME
MEASUREMENT
%
---
---
11