background image

Megatherm wood-pellet burner 

              MPB 90 Pro 

3. When thermostat is ON, the burner works at the maximum power  it is set.
4. When thermostat is OFF, the burner burns off

This is mostly suggested for low consumption houses (less than 3.000kg/year) or for 

connecting with timer.

 

If external control Yes

(Manufacturer's settings)

1. When thermostat is ON, the burner works at the maximum power  it is set.
2. When thermostat is OFF, the burner goes at maintain mode and keeps a small fire.

In both cases, when the thermostat is OFF, the CH pump stops.

11.

First use

1.

Ensure that the installation has been done according to this manual

2.

Ensure that the plastic pipe is not connected to burner's feeding pipe

3.

Fill the external feeder up with wood-pellet, by following the direction of paragraph
14 16, “Feeder filling procedure”. 

4.

Ensure that the feeder is full. Let the feeder working after the first pellets come out
of the feeder for 10-15 minutes (locate a plastic bag at the exit of the feeder)

5.

Empty the plastic bag and  place it back at the exit of the feeder.

6.

Connect again the power supply cable of the controller with the
feeder's cable for 

2 minutes.

7.

Weight the wood pellet which is in the bag (

for example 0.8kg

)

8.

Multiply it by 

30 minutes (0.8x30 = 24kg/hr)

. This is the

 feeder's performance

9.

Repeat the steps 4-8, 2-3 times

  until you make sure that you weight the right

quantity.

10. Place   this   value  

(i.e   24kg/hr)

  on   manufacturer's   settings   menu,   in   the

parameter 

“5. Feeder Performance” 

11.

Set the parameter “Feeder multiplier” at the right value, so the wood-pellet
is supplied from the external feeder, to be driven by the internal feeder to
the   burners   fire   chamber,   without   keeping   any   wood   pellet   inside   the
internal feeder.   

12. When the maximum power of the burner is reached , then  adjust the burners flame

by calibrating the air. The burning air is calibrated by changing the value of “Overflow
pellet's air” at Manufacturer's menu

19

Summary of Contents for MPB 150 Pro

Page 1: ...erm wood pellet burner MPB 90 Pro Wood pellet burner MPB 90 Pro Installation User Manual This manual is for the Installer Read understand and follow these instructions for safe installation and operat...

Page 2: ...thermostat 18 11 First use 19 12 Start of the burner 19 13 Stop of the burner 19 14 Cleaning burner s chamber 20 15 Restart the burner after an error 21 16 Feeder s filling rocedure 21 17 Self cleanin...

Page 3: ...and or clothing Always follow the instructions for operations and service Only wood pellets are to be used with this burner No other fuel is to be used in the burner NEVER BURN ANY TYPE OF CORN CHERRY...

Page 4: ...RESIS must be more than 10 o C Continuous mode The burner reaches the desired HEATING WATER TEMPERATURE and goes down at 3kW maintain When the boiler s temperature goes down to the temperature HEATING...

Page 5: ...4 400 77 400Kcal Maximum pellet consumption 8 18kg hr Lenght total 745mm Width 270mm Height with feeding pipe 360mm Height without feeding pipe 290mm Diameter 180mm Power supply 230Volt 80Hz Average p...

Page 6: ...se in the winter heating season 5 Chimney We recommend that you have a local chimney sweeper or other corresponding authority make an inspection and provide advice and instructions on the chimney meas...

Page 7: ...F BUTTONS 1 Changes the burner s working mode STOP IGNITION AUTOMATIC WORK 2 Return to the previous menu 1 Entry on the Menu s parameters 2 Saves the change of a parameter 1 In the Ignition MODE activ...

Page 8: ...0 8A ExternalFeeder 230V 2A 0 8A Internal Feeder 230V 2A 0 8A Burner s fan 230V 2A 0 8A CH pump 230V 2A 0 8A Thermostat 2 contacts open close max 24V 2A Protection Temperature STB 95 C Electric Fuse...

Page 9: ...re of useful warm water of the WUW buffer if the function is active On the screen appears which function is currently used by the driver The driver may work in three working modes STOP IGNITION AUTOMA...

Page 10: ...he mode would be automatically changed after detecting a flame by the sensor CLEANING The cleaning of the burner from he left ashes The cleaning function also as a blow down before ignition WORK Heati...

Page 11: ...URNACE SETTINGS A FUNCTION NO FUNCTION NAME SETTING UNIT SETTING RANGE MANUFACTURER SETTING 1 HEATING WATER TEMPERATURE C 35 85 65 2 CH PUMP ACTIVATION TEMPERATURE C 20 60 35 3 CH FURNACE HYSTERESIS C...

Page 12: ...W maintain to the maximum burner power i e30kW The CH FURNACE HYSTERESIS must be no more than 5 o C Analogue mode The burner reduces its power 1 3 for example from 30kW to 21kW 10 o C before the furna...

Page 13: ...DETECTOR TRESHOLD 5 90 10 10 FURNACE PROTECTION OVERHEAT C 60 90 80 11 STB TEMPERATURE C 90 110 90 12 FEEDER MULTIPLIER 1 5 2 13 IGNITION STABILIZATION Seconds 0 250 30 14 MAINTAIN STABILIZATION Seco...

Page 14: ...sions of the driver Description of manufacturer s settings 1 FEEDER FILLING TIME In this menu the manufacturer sets the time of the feeder s filling The time is the protection from filling up of the b...

Page 15: ...he step of 500grams Manufacturer Advise Can not be given any advise since it is depended on the feeder s angle and pellet quality Please follow the procedure on paragraph 11 First use 6 PELLETS FEEDIN...

Page 16: ...higher temperature than the one that was previously set is reached and when the CH pump is turned off The driver starts the CH pump automatically and switches off the burner The protection of the furn...

Page 17: ...h is located in the burner s fire chamber before starts the maintain mode Manufacturer Advise 60 240sec 15 MAXIMUM BURNER POWER In this parameter the installer can set the maximum burner power where t...

Page 18: ...ostat is ON the burner works at the maximum power it is set 2 When thermostat is OFF the burner goes at maintain mode and keeps a small fire In both cases when the thermostat is OFF the CH pump stops...

Page 19: ...g after the first pellets come out of the feeder for 10 15 minutes locate a plastic bag at the exit of the feeder 5 Empty the plastic bag and place it back at the exit of the feeder 6 Connect again th...

Page 20: ...n the boiler s water temperature reaches the desired temperature HEATING WATER TEMPERATURE the the power of the burner goes down ta 3kW Maintain mode 7 The burner works at Maintain mode till the boile...

Page 21: ...burner after an error 1 Turn off the burner by pressing the button ON OFF 2 Open the boiler s door and check the burners tube 3 Remove any ashes and impurities from burners tube 4 Close the door and s...

Page 22: ...ms For total fail safe security the burner is equipped with four safety systems 1 The plastic pipe connecting the feeder with the burner This tube will melt away from the burner in event of a too high...

Page 23: ...n 65 o C Back fire protection This is happened either the chimney s draught is no the appropriate or the burner hasn t been cleaned 1 If the temperature goes down to 60 o C and the photo sensor scans...

Page 24: ...Megatherm wood pellet burner MPB 90 Pro 20 Electrical diagram REG 03 2C 24...

Page 25: ...metal parts 2 years in electric parts feeder s motor air fan 1 year in electronic controller No waarranty is given for the heating element igniter Pellet heating systems Vasilika Thessaloniki 57006 G...

Reviews: