TRANSMITTER OPERATION
AVTM651070 Rev B Nov 2006
13
§
Passive 50/60 Hz Locating
FIBER-OPTIC CABLES
§
Multiple Grounded Telco Circuit
§
Inductive Connection
§
Telephone Direct Shield Connection
§
Passive 50/60 Hz Locating
NOTE:
The output will cycle when the LOW BAT indicator is activated to
inform you that a LOW BAT condition is present. You must use the
82 kHz high frequency setting when using the inductive connection
method.
Power Utility Connection
G
CAUTION
Turn the transmitter off before connecting or disconnecting
the red and black test leads.
This method, which has a range of up to 0.5 mi (0.8 km), uses the ground points
that are already exposed and available to you. Make connections as shown in
Figures 2 and 3. Because you are only transmitting the signal on the grounding
system, it is not necessary to disconnect the service.
Figure 2: Multiple Grounded Circuit Connection