background image

Using the Functions

HOLD

Press

Manually powering down the meter 

Press Ω/A button and “HOLD” button at the same time.

Powering ON

OFF

www.megger.com

MET1000-DE

11

Using the Functions

Summary of Contents for MET1000-DE

Page 1: ...User Guide EN MET1000 DE All in One True RMS Electrical Tester...

Page 2: ...cification of its products from time to time without notice Although every effort is made to ensure the accuracy of the information contained within this document it is not warranted or represented by...

Page 3: ...ed described in this user guide is in compliance with Directives 2014 30 EU and 2014 35 EU where they apply The full text of Megger Instruments EU declarations of conformity are available at the follo...

Page 4: ...tester is not operating properly or if it is wet Personal protective equipment must be used if hazardous live parts in the installation where the measurement is to be carried out could be accessible...

Page 5: ...origin of the low voltage mains supply outside the building and the consumer unit CATIII Measurement category III Equipment connected between the consumer unit and the electrical outlets CATII Measur...

Page 6: ...exhausted the tester is capable of measuring 45 VAC and or 35 VDC Timing Rating tr 30 seconds Recovery Time rt 240 seconds when measuring 300 V recovery time is necessary L R LED may light up when mea...

Page 7: ...ond test lead if fitted To carry out Single Pole Check test while firmly holding the MET1000 connect the test lead into a live circuit this will cause the hazard symbol to illuminate without any volta...

Page 8: ...kwise Phase Sequence L1 L3 L2 Left Source Grip firmly Terminal G Warning Phase Rotation Test works only on 3 phase 4 wire systems The result is unreliable on any other systems G Note It maybe necessar...

Page 9: ...Resistor Mode www megger com MET1000 DE 9 Resistor Mode...

Page 10: ...hold the meter above the barrier Barrier for hand guard G Warning The barrier guard on the meter provides maximum protection when holding the unit in normal use G Warning Remove the test leads from t...

Page 11: ...Using the Functions HOLD Press Manually powering down the meter Press A button and HOLD button at the same time Powering ON OFF www megger com MET1000 DE 11 Using the Functions...

Page 12: ...Torch Press 2 sec Powering ON Self diagnostic test or Press OFF G Warning Do not use the tester if a fault is indicated during self diagnostic test www megger com MET1000 DE 12 Using the Functions...

Page 13: ...Function Button Resistor Mode Current Mode Voltage Continuity Single Pole Mode Press Button Press Button 2 sec Press Button www megger com MET1000 DE 13 Using the Functions...

Page 14: ...Press here G Warning Replace the batteries as soon as the low battery indicator starts to flash to avoid false readings Remove test leads from meter before opening the battery cover www megger com MET...

Page 15: ...or CAT III or CAT IV environments use the test leads with the probe tip guard cap fixed firmly in place Without the probe tip guard cap the test leads can ONLY be used in a CAT II environment Make sur...

Page 16: ...Press here G Warning Do not attach test leads onto the back of the meter while measuring current For 19 mm power socket For most applications except current measurement www megger com MET1000 DE 16 T...

Page 17: ...N 61010 2 032 IEC EN 61010 2 033 IEC EN 61010 031 for CAT IV 600 V CAT III 1000 V IEC EN 61326 1 IEC EN 61243 3 Environmental Conditions Indoor Outdoor Use Pollution degree 2 Maximum Operating Altitud...

Page 18: ...ox 10 seconds The Auto Power On condition is not met Both buttons are not pressed The meter automatically turns off if one of the following conditions are met for approx 30 seconds The resistance is O...

Page 19: ...Range Resolution Accuracy With batteries 6 0 V 1 to 999 9 V 0 1 V 1 5 5D Without batteries 2 45 V to 999 9 V 0 1 V 1 For 65 Hz the minimum range is 8 0 V 2 Measurement without batteries is only avail...

Page 20: ...0 5D Frequency Response 45 Hz to 65 Hz Overload Protection AC DC 200 A Rotary Field Indication For 3 phase 4 wire system only Sensitivity 90 V to 1000 V Phase to ground Frequency Range 45 Hz to 65 Hz...

Page 21: ...ation No is WEE DJ2235XR Users of Megger products in the UK may dispose of them at the end of their useful life by contacting B2B Compliance at www b2bcompliance org uk or by telephone on 01691 676124...

Page 22: ...ation or handling Any implied warranties arising out of the sale of this product including but not limited to implied warranties of merchantability and fitness for a particular purpose are limited to...

Page 23: ...NOTES www megger com MET1000 DE 23 NOTES...

Page 24: ...00 723 2861 USA only T 1 214 333 3201 F 1 214 331 7399 E USsales megger com Megger AB Rinkebyv gen 19 Box 724 SE 182 17 Danderyd T 46 08 510 195 00 E seinfo megger com Megger USA Fort Collins 4812 McM...

Reviews: