background image

Megger Limited

Archcliffe Road 
Dover 

T + 44 (0) 1304  502100

Kent,  CT17 9EN

F + 44 (0) 1304 207342

England

E uksales@megger.com 

Megger 

4271 Bronze Way

T +1 (800) 723-2861 (U.S.A. only)

Dallas

T +1 (214) 333-3201 (International)

TX 75237-1019

F +1 (214) 331-7399

U.S.A.

E ussales@megger.com

Megger 

Z.A. Du Buisson de la Couldre 

23 rue Eugène Henaff

T +33 (0) 1 30.16.08.90

78190 TRAPPES  

F +33 (0) 1 34.61.23.77

France 

E infos@megger.com

Megger Pty Limited

Unit 26  9 Hudson Avenue

Castle Hill

T +61 (0)2 9659 2005

Sydney NSW 2125

F +61 (0)2 9659 2201

Australia

E ausales@megger.com

Megger Limited

T +1 416 298 9688 (Canada only)

110 Milner Avenue Unit 1

T +1 416 298 6770

Scarborough Ontario M1S 3R2

F +1 416 298 0848

Canada

E casales@megger.com

This instrument is manufactured in the United Kingdom.
The company reserves the right to change the specification or design without
prior notice.
Megger is a registered trademark.

Part No 6172-913- Edition 2 - Printed in England - 0206
www.megger.com

To replace batteries, 

disconnect test leads

. Remove the battery

cover and carefully remove the battery carrier.

Replace with new batteries. Do not mix old and new batteries

Warning: OBSERVE CORRECT POLARITY

. Incorrect battery

polarity could damage the instrument and invalidate the warranty.

Spare fuse

A blown fuse is indicated by the 

f

symbol. To replace the fuse:

Disconnect test lead and remove the battery cover, replace fuse
with spare provided: type:  500 mA (F) HBC 10 kA 500 V

Summary of Contents for MFT1500/2

Page 1: ...features and should not be regarded as a substitute for normal safe working practices Do not move the rotary switch positions while a test is in progress The LCD neon voltage indicators cannot reveal...

Page 2: ...lectricians should be used Symbols used on the instrument are F Caution risk of electric shock G Caution refer to accompanying notes t Equipment protected throughout by Double Insulation Class II c Eq...

Page 3: ...100 Warning Ensure the circuit to be tested is disconnected and isolated before starting testing Insulation testing M Range switch set to 250 V 500 V or 1 kV range Test Lead Options 1 or 2 For insulat...

Page 4: ...ed value may differ to the anticipated value This is caused by noise on the supply Repeating the test may result in a different reading if this is the case refer to page 13 of the handbook for possibl...

Page 5: ...the RED lead to 1st PHASE Bonded Metalwork Testing Hi Test Lead set OPTION 1 or 2 1 Connect the GREEN lead to the bonded metalwork 2 Connect the RED lead to PHASE 3 Supply voltage is displayed 4 The...

Page 6: ...Connect the test leads to the RCD as shown above 3 Press the YELLOW test button on the instrument or the switch probe On 1 2I the message 1999 ms is displayed after 2 seconds NOTE The message TrP will...

Page 7: ...enabled by a long press on the blue degree button As selective RCD test mode is enabled the MFT will emit a long beep and the display will show the exclamation mark symbol To disable Selective RCD mod...

Page 8: ...it 1 T 1 416 298 6770 Scarborough Ontario M1S 3R2 F 1 416 298 0848 Canada E casales megger com This instrument is manufactured in the United Kingdom The company reserves the right to change the specif...

Reviews: