Environmental
Operating temperature:

-10°C to 50°C

Storage temperature: 

-25°C to 65°C

Ingress protection (lid closed): 

IP65

Humidity: 

90% RH non-condensing at 40°C

Dimensions: 

305 x 194 x 360 (mm) (12 x 7.6 x 14.2 inches)

Weight: 

6.75 kg (15lb) approx

Voltage output accuracy (0°C to 30°C):  

0 - +4% of nominal test voltage at 100 M

load

Current measurement range: 

±0.01 nA to ±5 mA

Current measurement accuracy (23°C): 

±5% ±0.2 nA at all voltages

Display: 

Analogue/Digital 3 digits

Interference rejection: 

2mA rms 

Timer range: 

Counts up to 99 minutes from start of test

Test regimes

Auto IR

Lead set: 

Three flexible silicon insulated leads with compact clamp.

Safety: 

Meets the requirements of EN61010-1:2001 CAT III 300V

EMC: 

Meets the requirements of EN61326-1:1998 for use in heavy industrial areas.

Summary of Contents for MIT510

Page 1: ...M MIT510 5kV Digital Insulation Tester USER MANUAL...

Page 2: ...ces breakdown of the circuit under test may cause a loss of display presence of HV on the test leads will still be shown by a flashing red LED If this happens stop the test immediately by pressing the...

Page 3: ...r lead and charging the batteries 4 Quick start 5 Instrument controls and indicators 6 Power On Off button 6 V and V buttons 6 Test button 6 I button 6 B button 7 HV On LED 7 Charging indicator LED 7...

Page 4: ...y lifetime charge the battery after each use A completely exhausted battery will take 14 hours to recharge INTRODUCTION POWER LEAD AND CHARGING 4 The MIT510 is a compact microprocessor controlled high...

Page 5: ...orm a self check during which Ini is displayed After Ini disappears the instrument is ready for use 3 Check voltage at terminals display to be sure the load is safe to energise 4 Set test voltage requ...

Page 6: ...nly If the test voltage is changed during a test the new test voltage will be displayed briefly before the display again shows the voltage on the test leads After a test has been stopped the display s...

Page 7: ...voltage greater than 50 V from an internal or external source on the test inputs the LED flashes Charging Indicator LED This is a green LED next to the Power On Off button on the front panel When main...

Page 8: ...f the last test remains on the display until another test is started Digital Display The digital display shows the resistance or current being measured during a test The I button toggles between the t...

Page 9: ...d Voltage input range 85 260 V 50 60Hz Battery life 6 hours continuous testing at 5 kV Test voltages 250 V 500 V 1000 V 2500 V 5000 V Accuracy 23 C 5 to 1 T 15 1 T to 7 5 T 20 5 T to 10 T 5 counts Gua...

Page 10: ...ominal test voltage at 100 M load Current measurement range 0 01 nA to 5 mA Current measurement accuracy 23 C 5 0 2 nA at all voltages Display Analogue Digital 3 digits Interference rejection 2mA rms...