12

REPAIR AND WARRANTY

The instrument contains static sensitive devices, and care must be taken in

handling the printed circuit board. If an instrument’s protection has been

impaired it should not be used, but sent for repair by suitably trained and

qualified personnel. The protection is likely to be impaired if for example; it

shows visible damage; fails to perform the intended measurements; has

been subjected to prolonged storage under unfavourable conditions, or has

been subjected to severe transport stresses.

NEW INSTRUMENTS ARE GUARANTEED FOR 3 YEARS FROM THE

DATE OF PURCHASE BY THE USER.

Note:

Any unauthorized prior repair or adjustment will automatically

invalidate the Warranty.

INSTRUMENT REPAIR AND SPARE PARTS

For service requirements for Megger Instruments 

contact

:

Megger Limited

or

Megger    

Archcliffe Road   

Valley Forge Corporate Centre

Dover 

2621 Van Buren Avenue

Kent  CT17 9EN

Norristown PA 19403

England.

U.S.A.

Tel:  +44 (0) 1304 502 243

Tel:  +1 610 676 8579

Fax: +44 (0) 1304 207 342 

Fax: +1 610 676 8625      

or an approved repair company.

Returning and Instrument for Repair

If it is necessary to retun an instrument for repair, a returns Authorisation

number must first be obtained by contacting one of the addresses shown.

You will be asked to provide key information, such as the instrument serial

number and fault reported when the number is issued. This will enable the

Service Department to prepare in advance for the receipt of your

instrument, and to provide the best possible service to you.

The Returns Authorisation number should be clearly marked on the outside

of the product packaging, and on any related correspondence. The

instrument should be sent, freight paid to the appropriate address. If

appropriate a copies of the original purchase invoice and of the packing

note, should be sent simultaneously by airmail to expedite clearance

through customs.

For instruments requiring repair outside the warranty period a repair

estimate will be submitted to the sender, if required, before work on the

instrument commences.

Approved Repair Companies

A number of independent instrument repair companies have been

authorised for repair work on most Megger instruments, using genuine

Megger spare parts. A list of approved companies is available from the UK

address shown on this page. Spare parts are also available.

Summary of Contents for MIT510

Page 1: ...M MIT510 5kV Digital Insulation Tester USER MANUAL...

Page 2: ...ces breakdown of the circuit under test may cause a loss of display presence of HV on the test leads will still be shown by a flashing red LED If this happens stop the test immediately by pressing the...

Page 3: ...r lead and charging the batteries 4 Quick start 5 Instrument controls and indicators 6 Power On Off button 6 V and V buttons 6 Test button 6 I button 6 B button 7 HV On LED 7 Charging indicator LED 7...

Page 4: ...y lifetime charge the battery after each use A completely exhausted battery will take 14 hours to recharge INTRODUCTION POWER LEAD AND CHARGING 4 The MIT510 is a compact microprocessor controlled high...

Page 5: ...orm a self check during which Ini is displayed After Ini disappears the instrument is ready for use 3 Check voltage at terminals display to be sure the load is safe to energise 4 Set test voltage requ...

Page 6: ...nly If the test voltage is changed during a test the new test voltage will be displayed briefly before the display again shows the voltage on the test leads After a test has been stopped the display s...

Page 7: ...voltage greater than 50 V from an internal or external source on the test inputs the LED flashes Charging Indicator LED This is a green LED next to the Power On Off button on the front panel When main...

Page 8: ...f the last test remains on the display until another test is started Digital Display The digital display shows the resistance or current being measured during a test The I button toggles between the t...

Page 9: ...d Voltage input range 85 260 V 50 60Hz Battery life 6 hours continuous testing at 5 kV Test voltages 250 V 500 V 1000 V 2500 V 5000 V Accuracy 23 C 5 to 1 T 15 1 T to 7 5 T 20 5 T to 10 T 5 counts Gua...

Page 10: ...ominal test voltage at 100 M load Current measurement range 0 01 nA to 5 mA Current measurement accuracy 23 C 5 0 2 nA at all voltages Display Analogue Digital 3 digits Interference rejection 2mA rms...

Page 11: ...ncluded Accessories 3m lead set 8101 181 User guide on CD ROM 6172 929 Optional Accessories 3m lead set with straight jaw clamps 6220 797 15m lead set 8101 183 3m lead set insulated clamps Contact Meg...

Page 12: ...rument for Repair If it is necessary to retun an instrument for repair a returns Authorisation number must first be obtained by contacting one of the addresses shown You will be asked to provide key i...

Page 13: ......

Page 14: ...er com Megger Pty Limited Unit 26 9 Hudson Avenue Castle Hill Sydney NSW 2125 Australia T 61 0 2 9659 2005 F 61 0 2 9659 2201 E ausales megger com Megger Limited 110 Milner Avenue Unit 1 Scarborough O...

Reviews: