35
speed
torque
time
torque time
P60.17
Maximum
frequency
of open
loop brake
closed
Maximum
frequency of
open loop
brake closed
0.00~ P02.16
00.01Hz
10.00Hz
×
√
○
P60.18
Brake
feedback
detection
delay
Brake
feedback
detection
delay
0.00~10.00s
(Zero is disable)
0.01s 0.0s
×
√
○
Group P61:Special function parameters for lifting control
P61.05
Alarm
frequency
before
brake
release
Alarm
frequency
0~10.000Hz 0.01
1.00
×
√
○
P61.06
Overspee
d
detection
action
selection
Overspeed
detection
action
selection
0~2 1
1
×
√
○
P61.07
Overspee
d
threshold
Overspeed
threshold
80.0~200.0% 0.1%
120%
√
√
○
P61.08
Overspee
d
detection
time
Overspeed
detection
time
0.00~10.00s
If set to zero, not detected
0.01s 0.00s
√
√
○
P61.09
Power
limit
selection
Power limit
selection
0: Disable
1: For uplink
2: For uplink and downlink
1 2
×
√
○
P61.10
Maximum
power
limit for
uplink
Maximum
power limit
for uplink
0~100.0% 0.1%
100.0%
√
√
○
P61.11
Maximum
power
limit for
downlink
Maximum
power limit
for downlink
00.0~100.0% 0.1%
80.0%
√
√
○
P61.12
Power
control
accelerati
on and
decelerati
on rates
Power
control
acceleration
and
deceleration
rates
0.0~50.00Hz/s2 0.01
5.00Hz/s
2
√
√
○
Group P97: Protection and fault parameters