38
19: Abnormal current detection
circuit (Er.CUr), Hall or amplifying
circuit
22: External reference command
lost (Er. EGL)
23: Keyboard parameter copy
error (Er.CoP)
24: Poor auto-tuning (Er.TUn)
25: Local PG fault (Er.PG1)
26: Safety terminal failure
(Er.SAF)
27: Stall fault (Er.SoC)
28: Parameter setting error
(Er.PST)
29: Control board 24V power
short circuit (Er.24v)
30: Brake mechanical exception
(Er.bSF)
31: Expansion card fault (Er.oPT)
32: Overspeed fault (Er.oSP)
33: Grounding short circuit
(Er.GdF)
34: Large DEV deviation fault
(Er.dEv)
35: Load loss fault (Er.oFL)
36: Brake loosened (Er. FbL)
37: Brake contactor fault (Er.Fbr)
39: Motor over-temperature
(Er.oHL)
40: Reserved
41: Abnormal AI input fault (Er.AIF
abnormal analog input)
42: Inverter module temperature
sampling disconnection protection
(Er.THI)
43: Rectifier module temperature
sampling disconnection protection
(Er.THr)
44: Short circuit of ±10V analog
output power (Er.10v)
45: Abnormal internal
over-current reference (Er.rEF)
Note:
1. Er.drv fault can not be reset
until 10s later;
2. For continuous over-current
less than 3 times (including 3
times), it can not be reset until 6s
later; if it is more than 3 times, it