background image

Kessy

 

Prog.

 

Operation

 

manual

 

 

3

‐ 

3.  Kessy Prog operation instruction 

Turn on the programming tool by pressing ‘Return (Power)’ button for about 5 seconds. You can navigate 

on-screen menu by mini-joystick, ‘Enter’ and ‘Return’ buttons. Pressing on the center of mini-joystick works 
as ‘Enter’ button. Internal battery charge is indicated on a top right corner of the LCD-screen. If battery 
charge is low connect provided 5V charging device to mini-USB port. 

Onscreen menu sections: 

 

‘Program TP’ – key or chip registration; 

 

‘Make Dealer TP’ –  dealer key preparation; 

 

‘Test TP’– key or chip state check; 

 

‘Return TP’–  Kessy unit initial state recovery; 

 

‘Light’ – built-in lighter on/off; 

 

‘Settings’ – device parameters adjustment. 

                                                                                       

Pic.2  On screen menu. 

 

3.1.  Key programming function ‘Program TP’ 

This function includes key programming procedure and Kessy unit memory modification. 

Please pay attention

:

 keys or chips for registration must be unlocked. New keys or chips may be registered 

once. After that they became locked. Looked keys cannot be registered in another Kessy unit. 

Immobilizer systems with Kessy unit use only following types of transponders (HITAG2 group): 

 

PCF7936 – single chip; 

 

PCF7946 – transponder in original key without Keyless-Go; 

 

PCF7943 – transponder in original key with Keyless-Go. 

Electronic key with PCF7946 transponder and PCF7936 chip are fully functional right after registration 

procedure. Registered original key with PCF7946 is able to start the engine and to lock/unlock doors. 
PCF7936 chip is able to start the engine only. 

Keyless-Go key (with 

PCF7943

 transponder) registration is performed in two steps: 

 

Dealer key is prepared first with the help of ‘Make Dealer TP’ function (see chapter 3.2); 

 

Prepared dealer key may be registered by means of dealer equipment (VAS or VCDS) using received in 
step one PIN-code. 

‘Program TP’ function involves following steps: 

1)

 

Dismount Kessy unit, unplug connectors and take out internal board from its casing. 

2)

 

Plug clip-connector cable into Kessy Prog device. 

3)

 

Clean EEPROM chip pins on Kessy unit board. 

4)

 

Plug clip-connector to EEPROM chip as shown on pic.3. 

Please pay attention

:

 red wire on clip-connector must be linked up with first pin on 93c86 chip. 

Summary of Contents for Kessy Prog

Page 1: ...KessyProg Electronic keys registration device for vehicles equipped with Kessy immobilizer unit Operation manual...

Page 2: ...bles Kessy Prog recognizes software version and corresponding keys registration algorithm automatically after connection to Kessy unit Key registration in unit type 0 1 2 could be performed with only...

Page 3: ...keys cannot be registered in another Kessy unit Immobilizer systems with Kessy unit use only following types of transponders HITAG2 group PCF7936 single chip PCF7946 transponder in original key witho...

Page 4: ...Enter button You will see message New Project If Enter button is pressed EEPROM memory of Kessy unit will be stored in device s internal memory You should do it only at first time you connect to cert...

Page 5: ...sition number with mini joystick and confirm selection with symbol Maximum number of registered key is 8 so the position number must be equal or less than 8 New key may be registered on empty or alrea...

Page 6: ...istered in current Kessy unit Kessy Prog device will program it Writing TP message will appear and modify EEPROM content Writing EEPROM If programming process completes successfully you will see next...

Page 7: ...of Kessy unit will be stored in device s internal memory You should do it only at first time you connect to certain Kessy unit In case of later connection for second and so on key registration press...

Page 8: ...enu As function starts you will see Waiting inverter startup on LCD and later Take TP or cancel Now bring a key or chip as shown on pic 7 If key or chip reading is successful its type and state will b...

Page 9: ...ss Flashlight LCD backlight turnoff time Backlight time Beep volume for button pressing KBD volume Use left and right mini joystick position to adjust parameters Return button for exit DC charger conn...

Reviews: