background image

Kessy

 

Prog.

 

Operation

 

manual

 

 

4

‐ 

 

Pic.3  Connection with EEPROM chip on Kessy unit board. 

 

5)

 

Launch ‘Program TP’ function from onscreen menu. 

If Kessy unit memory reading performed successfully you will see such message on LCD: 

“Reading OK”.  

If electrical contact between clip-connector and 93c86 chip is bad you will see message “Waiting EEP 

Press a key to cancel” on LCD. When normal contact will be restored another message appears: “Reading 
OK”. Also you can cancel the operation by pressing ‘Enter’ or ‘Return’ button. 

If Kessy unit memory reading was unsuccessful message “Reading Error” occurs on LCD. In this case 

press ‘Enter’ button to return to menu. 

6)

 

After successful reading and “Reading OK” message press ‘Enter’ button. You will see message “New 
Project?” If ‘Enter’ button is pressed EEPROM memory of Kessy unit will be stored in device’s internal 
memory. You should do it only at first time you connect to certain Kessy unit. In case of later connection 
(for second and so on key registration) press ‘Return’ when you see “New Project?” message on LCD. In 
this case current Kessy unit memory content will be transferred to device’s RAM, and ROM will hold 
EEPROM initial state. This is important for recovery after any 
programming error. 

7)

 

Now Kessy Prog analyses software version and number of 
registered keys. This data will be displayed on LCD (pic.4). 

If Kessy unit has SW version 22, 23, 24 (Kessy Continental) - 

algorithm 3, you will see message “Connect the power connector 
then press OK”. It is necessary to plug crocodile connector cable as 
shown on picture 5 and press ‘Enter’ button. 

                                                                                                            

Pic.4  Kessy unit data display. 

Summary of Contents for Kessy Prog

Page 1: ...KessyProg Electronic keys registration device for vehicles equipped with Kessy immobilizer unit Operation manual...

Page 2: ...bles Kessy Prog recognizes software version and corresponding keys registration algorithm automatically after connection to Kessy unit Key registration in unit type 0 1 2 could be performed with only...

Page 3: ...keys cannot be registered in another Kessy unit Immobilizer systems with Kessy unit use only following types of transponders HITAG2 group PCF7936 single chip PCF7946 transponder in original key witho...

Page 4: ...Enter button You will see message New Project If Enter button is pressed EEPROM memory of Kessy unit will be stored in device s internal memory You should do it only at first time you connect to cert...

Page 5: ...sition number with mini joystick and confirm selection with symbol Maximum number of registered key is 8 so the position number must be equal or less than 8 New key may be registered on empty or alrea...

Page 6: ...istered in current Kessy unit Kessy Prog device will program it Writing TP message will appear and modify EEPROM content Writing EEPROM If programming process completes successfully you will see next...

Page 7: ...of Kessy unit will be stored in device s internal memory You should do it only at first time you connect to certain Kessy unit In case of later connection for second and so on key registration press...

Page 8: ...enu As function starts you will see Waiting inverter startup on LCD and later Take TP or cancel Now bring a key or chip as shown on pic 7 If key or chip reading is successful its type and state will b...

Page 9: ...ss Flashlight LCD backlight turnoff time Backlight time Beep volume for button pressing KBD volume Use left and right mini joystick position to adjust parameters Return button for exit DC charger conn...

Reviews: