O
PTO
C
ON
R
EFERENCE
F-7
In
st
a
lla
tio
n
S
p
ec
ifi
ca
tio
n
s
Specifications
All optically isolated outputs (Amp Enables, In Position bits, User I/O) and the V_USER input
are protected by automatic fuses. When tripped, these fuses automatically reset themselves
within a few seconds.
Operating temperature range
0 – 50
°
C
Isolation voltage
2500 V
RMS
V_USER voltage range
5 – 24 V
DC
V_USER voltage fuse trip current
1 A
Table F-5
Inputs
V_USER = 5 VDC
V_USER = 24 VDC
“On” threshold voltage
0.6 V max
19 V max
Propagation delay High-Low, t
PDHL
50
µ
sec max
20
µ
sec max
Propagation delay Low-High, t
PDLH
300
µ
sec max
400
µ
sec max
Table F-6
Outputs
V_USER = 5 VDC
V_USER = 24 VDC
“On” state output
voltage
0.25 V @ 250mA
0.25 V @ 250mA
“On” state output
current
250 mA max
250 mA max
“Off” state output
leakage current
25
µ
A max
25
µ
A max
Propagation delay Low-High, t
PDLH
10
µ
sec max
20
µ
sec max
Propagation delay High-Low, t
PDHL
300
µ
sec max
100
µ
sec max
Output
rise time
, t
R
5
µ
sec max
5
µ
sec max
Output
fall time
, t
F
75
µ
sec max
25
µ
sec max
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com