C
ONNECT
STC
S
TO
A
MPS
/M
OTOR
/E
NCODER
4-8
V
6
U
E
n
co
d
er
I
n
te
rf
a
ce
Figure 4-6
Example of Single-Ended Encoder Connection to V6U Rev 4
V6U
100
Ohms
Enc0_A-
Single-Ended
Encoder
I
B
A
+5V
GND
100
Ohms
Enc0_B-
100
Ohms
Enc0_I-
Vcc
Signal Gnd
5V_OUT
EIA 422
Line Receivers
Encoder Power
Single-Ended Encoder
to V6U/DSP Rev 4
Twisted pair
in cables*
Encoder
Output Type
R1
R2
CMOS (0 to +5V)
820
820
TTL (0 to +3V)
620
330
Note that each signal requires an indepen-
dent bias network in this configuration.
Put these bias circuits as close to the en-
coder as possible.
*Note:
Do not connect signal
ground to shield ground.
R1
R2
Gnd
5V_OUT
R1
R2
Gnd
5V_OUT
R1
R2
Gnd
5V_OUT
New
!
You must
provide
these bias
circuits.