Cashflow
©
2612 Engineers Handbook
©
MEI 2009
Page 29 G1
Status LED
A Status LED provides assistance in diagnosing the condition of the Cashflow
©
2612. The
following is a description of the LED codes, their meanings, and suggested remedial actions.
Signal
Meaning
Solution
LED ON
Indicates that the unit is
enabled and ready to
accept a note.
No action necessary.
LED OFF
Indicates that no power
has been applied to the
unit.
Check to ensure that power is applied.
1 Flash
Indicates that something
is obstructing the note
path.
Remove the magazine and LED housing;
inspect for foreign material.
2 Flashes
Indicates that the unit is
not enabled.
Verify configuration.
Check the coin tube levels in the coin
changer. Check the option switches in the
coin changer.
Note: Many machines disable the note
acceptor if the machine door is open and
the door switch is not activated or if the
machine is out of product.
3 Flashes
Indicates that the note
path needs cleaning for
optimum performance.
Remove the magazine and LED housing
and follow cleaning instructions (page 22)
to clean the note path.
4 Flashes
Indicates that something
is obstructing the note
path.
Remove the LED housing and look at the
note path on the housing and inside the
unit for foreign material; clean as
necessary.
5 Flashes
Indicates that the
magazine is removed
(the unit will not accept
without the magazine
attached).
Reinstall the magazine.
Continuou
s
Slow
Unit is defective.
Replace the unit.
Continuou
s
Fast
The magazine is full of
money.
Remove the money from the magazine.
Summary of Contents for CASHFLOW 2612
Page 1: ...MEI CASHFLOW 2612 NOTE VALIDATOR ENGINEERS HANDBOOK...
Page 6: ...Cashflow 2612 Engineers Handbook MEI 2009 Page 6 G1 Model Number Explanation Example...
Page 15: ...Cashflow 2612 Engineers Handbook MEI 2009 Page 15 G1 Dimensions...
Page 37: ...Cashflow 2612 Engineers Handbook MEI 2009 Page 37 G1 YOUR REPRESENTATIVE...