MEI CASHFLOW SC / SC Advance Page-12
MAINTENANCE
Note: Maintenance should be performed by a properly trained service technician.
Periodic maintenance can improve the performance and extend the working life of a note acceptor.
Additional attention may be required if the note acceptor becomes inoperable due to a jammed
object or if acceptance rates fall below normal.
Cleaning the Acceptor Module:
Note: You must remove the acceptor module from the chassis to open the front sensor area. Forcing the note path open without removing the
acceptor module from the chassis will damage the unit. Remember to turn off the machine (as per machine manufacturer) before performing
any cleaning.
1. Remove the acceptor module from the chassis.
2. Open the acceptor module by placing the palm of your hand on the front of
the module and your fingers around the top of the yellow cover as shown in the
diagram to the right. Pull the cover toward your hand and then lift up, opening
the module head fully.
3. Clear the note path area of any foreign objects.
4. Wipe the note path and sensor areas as needed with a soft damp cloth. Be
sure to also wipe the side walls of the optics housing. For stubborn dirt, a small
amount of mild non-abrasive soap may be added to the water before dampening
the cloth. Make sure no streaks or residual soap remain on the note path.
Note: CASHFLOW SC
®
and SC Advance
®
do not require the use of a cleaning card. Never use a petroleum-based product to clean
this device! Petroleum based products will damage the note path. Mild non-abrasive soap is preferred over alcohol.
Calibration:
CASHFLOW SC
®
and SC Advance
®
were designed not to require calibration.