background image

Installation 

The Series CV1000 has been designed for 

ease of mounting onto existing studs provided 

by Original Equipment Manufacturers (OEMs). 

Some machines may require brackets or 

faceplates to mount the unit. Refer to your 

machine operation manual or contact your 

distributor/OEM for more model-specific 

mounting information. 

1. Disconnect all power to the machine.

2. Secure the unit to the mounting studs   

 

with the appropriate hardware. 

3. Connect the interface harnesses from the  

 

machine to the unit. 

      4 - 

11/32 nuts

4. Apply power to the machine.

5. Check the Status LED for the “Steady   

 

ON” condition. If the LED is flashing,   

 

refer to the Status LED Chart.

6. Insert a bill to check acceptance. If    

 

enabled, the bill will be accepted.

7. Make a vend to ensure credit is received  

 

and proper change is paid out for the  

 

bill. 

 

     

 

    

 

   

 

The Series CV1000 is preconfigured during 

manufacture to accept U.S. 1.00’s. The 

Series CV1000 can be manually configured 

using an option coupon or by inserting a bill 

of the desired denomination . If the Series 

CV1000 is reprogrammed using a coupon 

with a different configuration, the new 

configuration will be the default. The coupon 

configuration will remain in memory even with 

the power off.       

COUPON CONFIGURATION 

PROCEDURE

1) Carefully copy the coupon from the Installation 

Guide.  Make copies of the coupon with a 

standard, carbon-based, non-color copier.  

The copies of the coupon must be the size of a 

U.S. $1 dollar bill.

2) Use a #2 pencil to fill in the blocks for desired 

options.

For correct operation, all 3 sections must be 

completed. Fill in only one block per line. 

Do 

not mark anywhere else or on the back of the 

coupon.

 

Complete section 1

 to enable desired 

bill denominations.  Enable 1 or 2 direction 

face up, or 4 way acceptance (which allows 

acceptance in all directions).

 

Complete section 2 

to enable desired 

bill denominations.  Fill in one block for 

each denomination.  Be sure to mark all the 

denominations.

Off

 

will reject bills of the selected denomination.

ACCEPT 

will accept bills of the selected    

                 denomination.

 

Section 3 - 

Not Applicable

 

Section 4

 - Not Applicable

 

Complete section 5

 to control the Bezel  

 Lights

.

  Flashing or constantly ON may  

 

be selected.

3) Locate the blue configuration button on the 

back of the unit.  Depress the button once to 

enter programming mode. The red LED Status 

light will flash rapidly.  Depressing the button  

again will exit the mode.
4) Insert the coupon face up and verify the 

settings were accepted.

ACCEPTED:  

Coupon returned imediately and 

the LED and the green arrows on the front of 

the bill validator flash 

10

 times when coupon is 

pulled out.

REJECTED:

   Coupon returned after ten 

seconds. The red LED and the green arrows on 

the front of the bill validator 

flash the 

number of 

times 

corresponding to the section improperly 

filled out.  Example: two flashes for improper 

section two.

Bill Configuration

An alternative to using the programming coupon 

is to program a CV1000 with a particular 

denomination of currency:

Press the Blue configuration Button on the back 

of the CV1000 Validator. The red LED status  

light,  next  to  the  blue  configuration  button,  will 

switch from steady ON to RAPIDLY FLASHING.

Insert a bill of the denomination you wish to 

enable or disable. The bill will be returned to you. 

If it is enabled, the red LED status light and the 

green arrows on the front of the bill validator will 

flash 

10

 times. 

If the bill is already enabled, it will be disabled, it 

will be returned to you, and the red LED status 

light  and  the  green  arrows  will  flash 

3

 times. 

Repeat the process to return to the former setting. 

7

 Flashes means the programming was 

not

 

accepted.

IMPORTANT!!

DO NOT leave the machine until the 

Status LED returns to steady ON.