MeiG
Product
Manual
of
SLM750
Module
SLM750
Module
Hardware
Design
Page 14, total 84 pages
Antenna interface
Include main antenna(ANT_MAIN),RX-D diversity
antenna(ANT_DIV) and GNSS antenna(ANT_GNSS)
Physical features
Size: 32.0×29.0×2.4mm
Weight: <5 g
Temperature range
Normal operating temperature: -30
℃~
+75
℃
Limited operating temperature: -40
℃~
+85
℃
Storage temperature: -45
℃~
+90
℃
Software upgrade
USB interface
RoHS
All hardware components fully comply with the EU
RoHS standard
Ambient humidity
5%~95%
ESD
VBAT,GND: Air discharge ±10KV,Contact discharge
±5KV
Antenna interface: Air discharge ±8KV,Contact
discharge ±4KV
Other interface: Air discharge ±1KV,Contact discharge
±0.5KV
Interface
144Pin LCC interface
LCC function interface
Power interface
USB2.0 High-Speed interface
UART interface
USIM/SIM card interface (support 3V
、
1.8V)
PCM interface
Hardware reset interface
Indicator light interface
Sleep control interface
Flight mode control interface
ADC interface
I2C interface
SGMII interface
SD card interface
WLAN interface
BT_UART interface
USB_BOOT interface
2.3 Functional diagram
The following figure shows a block diagram of SLM750 and illustrates the major functional
parts.
Power management
Baseband chip
DDR+NAND storage