VBAT_RF maximum current
0
1.8
A
Instantaneous voltage drop
(GSM 900 Maximum transmission
power level)
400
mV
USB_VBUS USB
detection
3.0
5.0
5.25
V
GPIO
Level power supply voltage of
digital IO
-0.3 1.8 2.0 V
Power supply voltage of shutdown
mode
-0.25
0.25 V
6.2 Temperature range
It is recommended that you use SLM750 at -30
℃
~+75
℃
and take temperature control
measures when applications are in the harsh environment conditions. At the same time, a limited
operating temperature range of the module should be provided. Under this temperature conditions,
some of the indicators may exceed. It is suggested that you store the applications under certain
temperature conditions. Modules beyond this range may not work or are damaged.
Table 32: Temperature range
Parameter
Min
Type
Max
Unit
Operation temperature
-30
+25
+75
℃
Limited operation
temperature
-40~-30 75~+85
℃
Storage temperature
-45
+90
℃
6.3 Electrical Characteristics of Interface Operation Status
VL: logical low level
VH: logical high level
Table 33: Logical level of normal digital IO signal
Signal
VL
VH
Unit
Min
Max
Min
Max
Digital input
-0.3
0.3*Vpin_min 0.3*Vpin_max Vpin_max V
Digital output
GND
0.2
Vpin_min-0.2
Vpin
V