Summary of Contents for MT7000 series

Page 1: ...MT7000 and MT8000series DK MEUI rEcHNo co LTD JAPAN...

Page 2: ...3 3 Transmitted LightOperation Brightfield 3 4 Usingthe Polarizer Slide lnAnalyzer 3 5 Photomicrography with35mmSLRandDigital SLRCameras 3 6 Photomicrography withDigital StillCameras 3 7 Connectrng a...

Page 3: ...gned Frame andOptics AllNewandlmproved PlanEpiscopic Objectives SlimCompact Footprint Infinity Corrected OpticalSystem Powerful 6V30WVertical Koehler llluminator Powerlul 6V30WTransmitted LightKoehler...

Page 4: ...power receptacle orincases where thereisa breakintheground conductor ordamage totheelectrical wirino onlyfusesofthespecified typeandrating areto beusedasrepracements switchoffthepower ano disconnect...

Page 5: ...e neglect misuse improper operation normal wear accident improper maintenance or modifications ofANYtype Thiswananty does nolcoverrepair or replacement wherenormal usehasexhausted thelifeof a partor i...

Page 6: ...ies areexcluded totheextent exclusions are permitted bylaw Thiswarranty givesyouspecific legalrights andyoumayalsohaveotherrights which varyfromstateto state Thiswanantysetsforththecustomer s exclusiv...

Page 7: ...rated illuminator MT8000 series Dropdowncoaxialstagecontrols 15 12 Focustension adjustment turntheknurled ringcounter clockwise to tighten thetension 13 Adjustable safetyknob turnleverclockwise to loc...

Page 8: ...ecords so thatyouhavetheproper information whenordering moreequipment ordering replacement partsor accessories orwhencalling fortechnical support Please makesurethatnosmallpieces orpartsareleft inthep...

Page 9: ...upplyis built in the microscope Plugthe powercordsetto the microscope andtheotherendintoa grounded outlet MT8000series Connect thecordfromthe incident illuminator to the standalone powersupply MA92710...

Page 10: ...adjusted to thisuser Otheruserswill havedifferent lP sanddifferent focusing abilities 3 0Operation interpupil larydistance ffi Oncethemicroscope hasbeensetupinitsworking location withallofthecomponent...

Page 11: ...t right position Thisadjustment willalsoneedto be donewhenever the bulbis changed Fieldof view Fused Incident lightpowersupply MTB000Series Vertical Adjustment Horizontal Adjustment 3 2lncidentLightOp...

Page 12: ...ervation ofyourspecimen moreor lesscontrast or resolving power Stopping downthediaphragm decreases resolution andbrightness butincreases image contrast and deothol focus 3 3Transmitted Light Operation...

Page 13: ...rspecimen moreor lesscontrast or resolving power Stopping downthe diaphragm decreases resolution andbrightness butincreases image contrast anddepthol focus PossibleBrightfieldModeOperational Problems...

Page 14: ...ted rightbelow theviewing headasshowninthedrawing below ltcanbeinserted orwilhdrawn fromtheoptical pathbygrabbing thechrome knobandsliding it east west in itsslot Theleveronthesiderotates thefilterbet...

Page 15: ...ding T2AdapterRingthat matches thecamerato be used Thetablebelowshowsthedifferent camerasandadapterringsthat canbe used T2 CameraAdapterRings T2 1 Canon T2 2 Minolta T2 3 PentaxK T2 4 PentaxS threaded...

Page 16: ...ershot G 1 G 2 MA151 30 43 MA151 30 43 MA151 40 42 M A 1 5 1 4 5 4 2 MA151 40 42 Canon Powershot G3 G5 MA151 30 41 MA151 30 41 MA151 40 40 MA151 45 40 MA151 50 40 Canon Powershot G6 MAl51 30 31 M A 1...

Page 17: ...Headwith IntegratedMale C mount ffi t 2 DK3000 C Mounts withLens MA151 35 03 0 3X MA151 35 04 0 45X MA151 135150 0 5x MA151 135115 1 0X MA151 135120 0 7X MA151 135125 2 5X Slip the C mount with lens o...

Page 18: ...ter with 0 7X lens Stips over existing photo tube MAl51 35 25 C MountAdapterwith 2 5X lens Stips over existing photo tube 4 0Maintenance and Cleaning LArr4E E Disconnect thepower cordonyourequipment p...

Page 19: ...looseparticles Fortoughdirt usea softlint free cottonclothmoistened withdistilled water lfthatfails tryusingmedical or reagent gradeisopropyl alcohol Cleaning the Objectives orxc nI Objectives should...

Page 20: ...ed image lromthemicroscope please rejertothecorresponding chapters ofthismanual under theproper operation mode brightfield elc Electrical Problems Electrical problems caninclude Thelamponthemicroscope...

Page 21: ...efusecapfromthefuseholder Removethe blownfusefromthefusecap Replace thefusewiththeCORRECT typeandratingwhichis 30W HalogenSystems MA327 3 Amp 250V 5 X 20mm o Reinstall thefuseholderwiththe newfusein p...

Page 22: ...d o Waituntilthe housing andbulbhavecooledsufficiently o Loosen theclampscrewanddirectthebacking plateso it can be removed fromthehousing o Remove thedefective lamp o Placea newlampintothesocketwhilea...

Page 23: ...ing theglass Noticethebulbis wrappedin plastic Useit to avoidtouching theglassenvelope duringinstallation o Be surethe bulbis pushedin as faras possible therebyaligning thefilament in the illuminator...

Page 24: ...rect youto theclosest authorized MeijiTechno Dealer inyour area Callustollfree 800 832 0060 Monday through Friday gam SpmPST Viewing Heads Description PartNumber Siedentopf typebinocular head 30 incli...

Page 25: ...1 Ceramic coated flattopstage191mmx 126mmwithright handed withdropdown coaxial controls 100mm x 100mmx ytravel included MA958 Photo Video attachment for MA957Ergonomic headonly MA809 10 Replacement 11...

Page 26: ...Filter I Application ND50 NeutralFilteror ND Filter Greyfiltersor neutral density filters areusedto I attenuate allfrequencies of lightequally resulting inpreservation ofcolor I temperature TheND50fil...

Page 27: ...rrf y Weight Dimension Binocular headtype424 Smm Trinocular headtype424 Smm __ 111 D x 471mm H x 212mm D x 526mm H x 212mm 263 MT7000 263 MT8100 W 8 5k9for MT7000and9 0k9for MT8000 W 9 2k9 forMT7100 a...

Page 28: ...e Phone Fax E mail Web Phone Fax E mail Web 049 259 0111 049 259 0113 meiji meijitechno co jp http iwww meijitech no co jp 800 832 0060 408 e70 4799 408 e70 5054 sales meij itechno com http www meijit...