Operating instructions

 

 

Integrated reverse osmose 

 

GiO Module 

 

 

TRANSLATION OF THE "ORIGINAL OPERATING INSTRUCTIONS" 

 

The original operating instructions can be downloaded from: https://partnernet.meiko.de 

 

 

 
 
 
 
 

 

 

 

 

 

 

 

Summary of Contents for GiO Module

Page 1: ...on and construction MEIKO Maschinenbau GmbH Co KG Englerstr 3 D 77652 Offenburg Tel 49 781 203 0 Fax 49 781 203 1121 Operating instructions Integrated reverse osmose GiO Module TRANSLATION OF THE ORIG...

Page 2: ...Installation 4 3 1 Building requirements 4 3 2 GiO with AirConcept 5 3 3 Installation 6 3 4 Circuit function diagram 7 3 4 1 Circuit function diagram option connection BA system separator as per EN 17...

Page 3: ...203 1121 1 Introduction and general information These operating instructions for the integrated reverse osmosis gio module are a supplement to your dishwasher s operating instructions Only work with...

Page 4: ...water connection Free of particles 10 m Iron 0 1 mg l Manganese 0 04 mg l Chlorine free chlorine 0 1 mg l standard diaphragm Chlorine free chlorine 0 1 to 2 0 mg l chlorine resistant diaphragm Potassi...

Page 5: ...we stipulate that a chlorine resistant diaphragm must be used NOTE When replacing the standard diaphragm 9703526 or 9651200 60 for the new chlorine resistant diaphragm 9721935 the filter casing and fi...

Page 6: ...t not be changed With a standard diaphragm The 10 m filter insert item no 9695683 must be replaced every 6 months 7 filter casing length 178 mm With a chlorine resistant diaphragm The 10 m filter inse...

Page 7: ...Tel 49 781 203 0 Fax 49 781 203 1121 3 4 Circuit function diagram Drain set Drain concentrate transparent hose Appliance with integrated reverse osmosis GiO Module Waste water pipe of the machine Dra...

Page 8: ...1 Circuit function diagram option connection BA system separator as per EN 1717 Drain set Drain concentrate Transparent hose Waste water pipe from the machine Drain pump Supply untreated water Reinfo...

Page 9: ...l FV 40 2 FV40 2G K FV 60 2 TopClean 60 ET8 M OS UPster U 500 M2 UPster U 500G M2 Machine Cover connection s hose electrical cable Drain set Towards local drain pipe see technical sheet For connection...

Page 10: ...ET 15 M OS DV200 2 FV130 2 FV250 2 DV270 2 UPster H 500 M2 Supply untreated water Drain concentrate Clean water outlet Connection s bush electrical cable Machine Cover connection s hose electrical cab...

Page 11: ...n GiO Module M iClean U serie Drain set Towards local drain pipe see technical sheet For connection do not use more than three 90 bends Connection set Untreated water re move Reinforced hose Option Co...

Page 12: ...ction plan GiO module M iClean U Series for the UK Drain set Towards local drain pipe see technical sheet For connection do not use more than three 90 bends Connection set Untreated water re move Rein...

Page 13: ...must always be connect This is the only way to ensure that the drain line is safely separated from the osmosis module The scope of delivery includes a black plastic hose Always open the water inlet b...

Page 14: ......