Operating instructions dishwashing machine model
K-Tronic
Datei:2K_9626212_Betriebsanleitung-MIKE_EN_2005-12-01.doc
gültig ab: 2003-01
Update: 2004-05-07
Ident-Nr.:
9619165
28/38
W e reserve the right to change execution and construction!
MEIKO Maschinenbau GmbH & Co. KG, Postfach 2040, D-77652 Offenburg, Tel.: 0781/203-0, Fax: 0781/203-1174
16 Maintenance
recommendation
Service step
c
d
e
f
Maintenance
Cleaning works
Daily
At least once
quarterly
At least once
or twice a
year
but
every
1000 h
At least once
yearly
but
every
2000 h
VERY IMPORTANT:
Whenever any electrical components are disconnected and
reconnected, replaced or repaired, a safety test must be
conducted, at least on these components!!!
Tip:
Exchange the wearing parts designated „V“ from the spare parts list.
1. Basket conveyor
Check drive motor
Check drive motor for exterior damage
Check drive motor for quiet running
Check current consumption
(
I
N
see wiring diagram)
Check ventilation grid for cleanliness
Conveyor overload switch activation
Check the transport cradle guide blocks and the link block of the drive
plate for wear.
Check the conveyor overload switch by simulating an overload. Correct the
pre-tension on the spring if required.
Check that the conveyor cradle moves easily
2. Wash pumps
Check pump motor
Check motor for exterior damage
Check current consumption
(
I
N
see wiring diagram)
Check motor for quiet running (bearing damage)
Check ventilation grid for cleanliness
Check wash pump
Check sliding ring seal for watertightness (external visual check)
Replace sliding ring seal
ca. alle 2 Jahre
alle ca. 3000 h
Check pump impeller for damage
Check pump housing for damage
Check pump screen (suction side) (if present)
Check pump screen condition
Thoroughly clean inside of pump screen
Clean outside of pump screen
Summary of Contents for K-Tronic
Page 1: ......