13 / 16
9680928
10 Replacing the blade
Dismount the TopCut B and fix in place on a stable workbench. Wear robust working
gloves when working on the TopCut.
Release the screw on the blade retainer (M5 x 6
– Phillips head)
Pull out the blade
Fit a new blade, MEIKO Article no.: 9658626
Tighten the M5 screw
1. Functional check: make sure the blade holder is mobile
Push the TopCut into the bracket on the washing chamber door and secure in place
with screws.
2. Functional check: Insert a filled urine bag (you may prefer to fill the bag with
water) into the TopCut holder; close the washing chamber door and check the results.
11 Final decommissioning
In case of intended use, the holder is disinfected. On decommissioning, remove the blade
and recycle the holder. The holder is completely manufactured from stainless steel. If the
disinfection status is unclear, we recommend disinfecting the holder in a disinfection
device prior to disposal.