background image

9680928 

4 / 16 

 

 

2.1  Suitable bag types 

 
Bag types suitable for the TopCut B: 
 
The following bags may be inserted, cut and emptied. 
 

TopCut B 

Manufacturer 

Model 

Capacity 

in ml 

Baxter 

Physioneal 40 

1500 

5000 

Dianeal PD1 

1500 

5000 

Clear Flex Infusion bag 

2000 

Bbraun 

Ureofix 

1500 

3500 

Secretion bag 

1500 

2000 

5000 

Vacufix 

1000 

2000 

3500 

Curion 

CuriBag 

1500 

Dahlhausen 

Drainage bags 

500 

Gambrosol 

trio 40 

2500 

5000 

Kendall 

mono-FLO 

2000 

Oufora 

Standard 

1500 

Sarstedt 

MPL UM500 

1800 

3000 

UM500 

1800 

3000 

Serres 

Suction Bag 

1000 

2000 

3000 

Serumwerke 

Bernburg AG 

Isotonic saline solution 

1000 

Smiths medical 

medex Drainage bags 

1000 

Tear pfm medical AG 

Urine bag 

1500 

2000 

Thermofina La Precision 

Ureoplast-V  

(Valve Anti-Reflux) 

2000 

 
 

 

 

Summary of Contents for TopCut B

Page 1: ...pdate 2021 03 www meiko global com Operating instructions Universal vessel holder with urine and secretion bag cutter TopCut B Translation of the Original operating instructions Read operating instruc...

Page 2: ...NED USE 3 2 1 Suitable bag types 4 3 STRUCTURE 6 4 FUNCTIONAL DESCRIPTION 7 5 OPERATION INSERTING THE BAG 8 6 CLEANING 9 7 SAFETY INSTRUCTIONS 10 8 NOTES ON INSUFFICIENT FUNCTIONALITY OF THE TOPCUT 11...

Page 3: ...we reserve the right to make changes to the scope of supply concerning the design equipment and technical features at any time No claims may therefore be based on the details the images or the descri...

Page 4: ...ofix 1500 3500 Secretion bag 1500 2000 5000 Vacufix 1000 2000 3500 Curion CuriBag 1500 Dahlhausen Drainage bags 500 Gambrosol trio 40 2500 5000 Kendall mono FLO 2000 Oufora Standard 1500 Sarstedt MPL...

Page 5: ...5 16 9680928 BBraun Worek with outlet Curion CuriBag Kendall mono FLO BBraun Vacufix Serres 2000ml 3000ml...

Page 6: ...9680928 6 16 3 Structure Locking lever TopCut B Knives...

Page 7: ...inally at one corner 30 to 40 mm the bag then drains autonomously when the washing chamber is closed The bag is cut at the centre 30 to 40 mm the bag then drains autonomously when the washing chamber...

Page 8: ...basket in the direction of the arrow with your left hand Press down the lever with your right hand palm and simultaneously push the bracket forwards until the lever engages in front of the retaining...

Page 9: ...mme has finished it means the bag has been emptied and disinfected and can be removed 6 Cleaning When the programme has finished it means the bag has been emptied and disinfected externally The TopCut...

Page 10: ...anger of injury Please observe proper use of the cleaning and disinfection device Any other use or operations could cause damage and risks for which we can accept no responsibility Wear personal prote...

Page 11: ...unt or damaged and thus unable to penetrate the foil Call in authorised staff to replace the blade If the mechanical system is bent or does not run smoothly call in authorised staff to repair or repla...

Page 12: ...s when removing housing parts and when working inside the machine Before removing the TopCut make sure that the blade has retracted correctly and that the holder is free of soiling In dismounted state...

Page 13: ...TopCut into the bracket on the washing chamber door and secure in place with screws 2 Functional check Insert a filled urine bag you may prefer to fill the bag with water into the TopCut holder close...

Page 14: ...9680928 14 16 12 Spare parts list BAG CUTTER TOPCUT B 4 3 1 7 8 6 5 7 14 2 2 13 13 12 11 10 9 3 4 TopCut B...

Page 15: ...0308034 ZYLINDERSCHRAUBE PAN SCREW VIS CYLINDRIQUE 6 0340021 SCHEIBE DIN 125 A LIMPET DIN 125 A RONDELLE DIN 125 A 7 9667198 LAUFROLLE ROLLER POOULIE 8 9658626 MESSER KNIFE COUTEAU 9 9658624 WELLE 8X...

Page 16: ...Valid from 2009 09 Update 2021 03 MEIKO Maschinenbau GmbH Co KG Englerstra e 3 77652 Offenburg Germany www meiko global com info meiko global com Design and construction subject to change without prio...