background image

Table of Contents

1

Imprint

1

2

microSync Introduction

2

3

Technical Specifications microSync Chassis

3

4

Important Safety Information

4

4.1

Important Safety Instructions and Protective Measures . . . . . . . . . . . . . . . . . . . . . . . . .

4

4.2

Used Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5

4.3

Security during Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7

4.4

Protective Conductor- / Ground-Terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

9

4.5

Safety during Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

9

4.6

Safety during Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

10

4.7

Handling Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

10

4.8

Cleaning and Care . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

11

4.9

Prevention of ESD Damage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

11

4.10 Return of Electrical and Electronic Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

12

5

microSync HR102/DC - Connectors

13

5.1

GPS Antenna . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

13

5.2

Programmable pulse output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14

5.3

Time Code AM (modulated) Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14

5.4

Frequency Synthesizer Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

15

5.5

RS-232 COMx Timestring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

15

5.6

Status Indicators - CPU and Receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

16

5.7

USB Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

17

5.8

LAN Network Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

17

5.9

DMC X2 Terminal Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

18

5.10 Fiber Optic - Programmable pulse Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

19

5.11 DMC X1 Terminal Connector / DC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . .

20

6

GNSS Satellite Navigation

22

6.1

Time Zone and Daylight Saving . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

23

7

Installation GPS Antenna

24

8

Starting of Operation

28

8.1

Initial Network Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

29

8.1.1

Network configuration with the mbgOSWizard . . . . . . . . . . . . . . . . . . . . . . . . .

30

8.2

Initial Start of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

31

9

Technical Appendix

33

9.1

Technical Specifications GNSS Receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

33

9.2

Configuration Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

35

9.3

Protocols and Profiles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

35

9.4

Compliances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

35

10 Technical Appendix - GPS A Accessories

36

10.1 Antenna Cable: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

38

10.2 Antenna Short-Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

38

10.3 Technical Specifications - MBG S-PRO surge protection . . . . . . . . . . . . . . . . . . . . . . .

39

10.3.1 MBG S-PRO - Physical Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

41

10.3.2 Installation and Grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

41

11 RoHS and WEEE

42

Date: 29th July 2021

microSync

Summary of Contents for HR102/DC

Page 1: ...TECHNICAL REFERENCE microSync HR102 DC 29th July 2021 Meinberg Funkuhren GmbH Co KG ...

Page 2: ......

Page 3: ... Indicators CPU and Receiver 16 5 7 USB Interface 17 5 8 LAN Network Interfaces 17 5 9 DMC X2 Terminal Connector 18 5 10 Fiber Optic Programmable pulse Output 19 5 11 DMC X1 Terminal Connector DC Power Supply 20 6 GNSS Satellite Navigation 22 6 1 Time Zone and Daylight Saving 23 7 Installation GPS Antenna 24 8 Starting of Operation 28 8 1 Initial Network Configuration 29 8 1 1 Network configuratio...

Page 4: ...12 Declaration of Conformity 43 microSync Date 29th July 2021 1 ...

Page 5: ...n GmbH Co KG Lange Wand 9 31812 Bad Pyrmont Germany Phone 49 0 52 81 93 09 0 Fax 49 0 52 81 93 09 230 Internet https www meinbergglobal com Mail info meinberg de Date 2021 03 17 Manual Version 1 04 2 Date 29th July 2021 microSync ...

Page 6: ...ifferent receiver variants e g the 72 channel GNSS receiver for GPS Galileo GLONASS and BeiDou The sync optimized operating system supports NTP PTP IEEE 1588 and a variety of protocols for management tasks Product Highlights Powerful IEEE 1588 PTP Time Server incl IEC IEEE 61850 9 3 IEEE C 37 238 High performance S NTP server Half rack solution for a space efficient design Different Oscillator opt...

Page 7: ...y Heat 85 C 185 F Storage Temperature 30 to 70 C 22 to 158 F Relative Humidity 5 to 95 non condensing at 40 C 104 F Operating Altitude up to 4 000 m 13 123 ft above sea level Atmospheric Pressure 615 to 1 600 hPa Physical Dimensions 43 7 mm 1 72 inch 31 8 mm 1 25 inch 465 1 mm 18 31 inch 482 6 mm 19 inch 236 mm 9 29 inch 251 mm 9 88 inch 223 mm 19 inch 4 Date 29th July 2021 microSync ...

Page 8: ... signal words you may only continue if you have understood and fulfilled all requirements In this documentation dangers and indications are classified and illustrated as follows DANGER The signal word indicates an imminently hazardous situation with a high risk level This notice draws attention to an operating procedure or similar proceedings of which a non observance may result in serious persona...

Page 9: ...rischen Schlages Caution risk of electric shock IEC 60417 5041 Vorsicht heiße Oberfläche Caution hot surface IEC 60417 6056 Vorsicht Gefährlich sich bewegende Teile Caution moving fan blades IEC 60417 6172 Trennen Sie alle Netzstecker Disconnection all power plugs IEC 60417 5134 Elektrostatisch gefährdete Bauteile Electrostatic Sensitive Devices IEC 60417 6222 Information generell Information gene...

Page 10: ...may only be used for the purpose described in this manual In particular the given limits of the device must be observed The safety of the installation in which the unit is integrated is the responsibility of the installer Non observance of these instructions can lead to a reduction in the safety of this device Please keep this manual in a safe place This manual is intended exclusively for electric...

Page 11: ...nal measures e g Installation in an air conditioned control cabinet required Transport Unpacking Installation If the unit is brought into the operating room from a cold environment condensation may occur wait until the unit is temperature controlled and absolutely dry before operating it When unpacking setting up and before operating the equipment be sure to read the information on the hardware in...

Page 12: ...rical shock and may destroy other equipment Ensure that all necessary safety precautions have been taken Make all connections to a unit before turning on the power Observe the safety instructions on the device see safety symbols The metal housing of the device is grounded It must be ensured that enough air and creepage distances to neighboring voltage carrying parts are provided during assembly in...

Page 13: ... dusty as there is a danger of overheating during operation Disturbances during operation can result Normal Operation The normal operation and the observance of the EMC limits electromagnetic compatibility are only ensured if the housing cover is properly installed and when the doors are closed cooling fire protection shielding against electrical magnetic and electromagnetic fields Switch off in f...

Page 14: ... to considerable risks for the user and result in a loss of warranty as well as an exclusion of liability Danger due to moving parts keep away from moving parts Device parts can become very hot during operation Do not touch these surfaces If necessary switch off the unit before installing or removing any equipment and allow it to cool down 4 7 Handling Batteries CAUTION The lithium battery on the ...

Page 15: ...pare removal and installation of assemblies Unload yourself for example by touching a grounded object before touching assemblies Ensure that you wear a grounding strap on the wrist when working with such assemblies which you attach to an unpainted non conductive metal part of the system Use only tools and devices that are free from static electricity Transporting Assemblies Assemblies may only be ...

Page 16: ...he WEEE Directive The product symbol on the left indicates that this electronic product must not be disposed of in domestic waste Return and Collection Systems For returning your old equipment please use the country specific return and collection systems available to you or contact Meinberg The withdrawal may be refused in the case of waste equipment which presents a risk to human health or safety...

Page 17: ...enna cable Output voltage 15 V 100 mA via antenna cable Connection type BNC female N standard female Cable type Coaxial cable shielded max 300 m to RG58 max 700 m to RG213 WARNING Working on the antenna system during thunderstorms Danger to life due to electrical shock Do not carry out any work on the antenna system or the antenna cable if there is a risk of a lightning strike Do not carry out any...

Page 18: ...Cyclic Pulse Single Shot Timer Idle All Sync Time Sync Position OK DCF77 Marks Pulse Per Hour Pulse Per Min DCLS Time Code Serial Time String Synthesizer Frequency PTTI 1PPS 5 3 Time Code AM modulated Output Signal outputs Unbalanced sine wave signal Signal level 3 Vpp 1 Vpp MARK SPACE into 50 Ohm Carrier frequency 1 kHz IRIG B Connection type BNC female Cable shielded coax line microSync Date 29t...

Page 19: ...udrate framing 19200 8N1 default Time string Meinberg Standard default Assignment Pin 2 RxD receive Pin 3 TxD transmit Pin 5 GND ground Connector 9pin D SUB male Cable data cable shielded PC connector 1 1 Synchronization with PPS String Pin 1 PPS In Signal level TTL Pulse length 5 µs active high Pin 2 String In RxD The following timestrings time telegrams can be used NMEA RMC NMEA ZDA Meinberg Sta...

Page 20: ...r switched to the local clock N Network green All monitored network interfaces are connected Link up red At least one of the monitored network interfaces is faulty A Alarm off No error red General error REC Fail red No synchronization Ant red No synchronization resp no antenna connected or short circuit on the antenna line green Antenna connected and clock is synchronized Nav green Positioning com...

Page 21: ... 1 Management NTP 10 100 1000Mbit RJ45 or 1000FX LAN 2 Management 10 100 1000Mbit RJ45 or 1000FX NTP PTP Master and Slave LAN 3 Management 10 100 1000Mbit RJ45 or 1000FX NTP PTP Master Recommended and tested Transceivers from other Vendors MULTI MODE AVAGO AFBR 5710PZ FINISAR FTLF8524P3BNL SINGLE MODE AVAGO AFCT 5710PZ FINISAR FTLF1318P3BTL RJ 45 AVAGO ABCU 5740RZ FINISAR FCLF8521P2BTL 18 Date 29t...

Page 22: ... isolated TTL active high 250mA short circuit proof TCA Time Code Amplified DCLS output with large output current Pin 9 PP 5 program pulse optocoupler Pin 10 GND ground Pin 11 GND ground Pin 12 GND ground Pin 13 GND ground Pin 14 TC In Time Code DCLS TTL isolated Pin 15 not used Pin 16 not used Status LEDs PP 5 PP 8 Status of Pulses Out 9 8 16 1 9 8 16 1 To the X2 device connection 16 pin socket w...

Page 23: ...Pulse outputs Pulse Per Second Cyclic Pulse Single Shot Timer Idle All Sync Time Sync Position OK DCF77 Marks Pulse Per Hour Pulse Per Min DCLS Time Code Serial Time String Synthesizer Frequency PTTI 1PPS ATTENTION Unused connectors of optical interfaces should always be provided with a protective cap The optical interface contains a light emitting diode LED 20 Date 29th July 2021 microSync ...

Page 24: ... negative potential of operating voltage Pin 2 not used Pin 3 PP 1 programmable pulse Pin 4 PP 2 programmable pulse Pin 5 PP 3 programmable pulse Pin 6 PP 4 programmable pulse Pin 7 REL NO Error Relay normally open Pin 8 REL CO Error Relay common Pin 9 DC in positive potential of the operating voltage Pin 10 not used Pin 11 PP 1 programmable pulse Pin 12 PP 2 programmable pulse Pin 13 PP 3 program...

Page 25: ...potential free contact which is controlled directly by the used reference clock GPS GNS GNS UC Normally when the reference clock has synchronized the the relay contact NO switch to active If the reception is disturbed or the device is switched off the relay contact NC is active Technical Specification Switching Voltage max 60 V DC Switching Current max Imax 400mA Switching Load max 24 W Response T...

Page 26: ...emeris parameters must be evaluated to compute the receiver s position and clock offset almanac parameters are used to check which satellites are in view from a given receiver position at a given time Each satellite transmits its own set of ephemeris parameters and almanac parameters of all existing satellites GPS was installed by the United States Department of Defense and provides two levels of ...

Page 27: ...e GPS was initiated in 1980 The current number of leap seconds is part of the navigation message supplied by the satellites so the internal real time of the GNS is based on UTC time scale Conversion to local time and annual daylight saving time can be done by the receiver s microprocessor if the corresponding parameters are set up by the user 24 Date 29th July 2021 microSync ...

Page 28: ...ded Selection of the Antenna location To receive enough satellites select a location that allows an unobstructed view of the sky otherwise there may be problems with the synchronization of the system There should be no obstacle in the line of sight between the antenna and the satellites In addition the antenna must not be installed under high voltage lines or other electrical light or electric cir...

Page 29: ... caused by lightning strikes can be transmitted via the antenna cable and may cause damage to the receiver The receiver is pro tected against these effects by using the MBG S PRO surge protection Being installed in a waterproof housing the MBG S PRO is also suitable for outdoor installation Mein berg recommends the indoor installation as soon as possible after the antenna cable enters the building...

Page 30: ...ble to the socket of the surge protection Earth cable to PE rail Cable circa 1 5 mm Ø attached to the surge protection as short as possible 4 The next step is to connect the supplied coaxial cable between the surge protector and receiver N Norm female N Norm male SMA female BNC female N Norm male N Norm female BNC male Receiver Antenna splitter SMA male M B G S P R O Optional microSync Date 29th J...

Page 31: ...pensate the signal propagation time of the antenna cable therefore you need to enter the length of the antenna cable in meters or the compensation time in nanoseconds into the settings of your receiver Antenna Cable Length m The receiving satellite signal is delayed by the used coaxial cable Cable Delay Usage RG58U 5 ns m for GPS and GNS UC receivers H155 4 ns m for GNS and GNM receivers By enteri...

Page 32: ...istributions include Ubuntu Mint Linux Debian SUSE Linux CentOS and others The software is delivered on the USB stick included in the scope of delivery and does not need to be in stalled or copied on the PC The Meinberg Device Manager can be started directly from the USB data carrier The computer must be connected to the network in which the microSync system is connected The software is downloadab...

Page 33: ...bergglobal com english sw mbg devman htm If the network settings of your PC do not allow a connection to the microSync system you have to adjust the settings of your network adapter At delivery the microSync system has the following network settings IP v4 address 192 168 19 79 Netmask 255 255 255 0 Gateway This entry is empty DHCP disabled Username admin Password timeserver If you do not have acce...

Page 34: ...twork configuration with the mbgOSWizard After the successful connection via the serial console as described in chapter Initial Network Configura tion you can now use the Meinberg OS Wizard to configure the IP address for the first time Select the same subnet mask as for your network adapter and an IP address which is located in the same subnet First start the wizard with mbgOSWizard sh after conf...

Page 35: ...roSync systems that have a serial or a network connection are recognized by the Meinberg Device Manager and will be listed then Found systems are displayed with a green dot Modules that are no longer recognized are displayed with a red dot Modules whose password or password user name combination is unknown will be marked with a red x Use the corresponding checkbox to select the device with which y...

Page 36: ...icate with your sys tem Please make sure that the port is not blocked by your firewall configuration Save Credentials With this checkbox you ensure that the Device Man ager has remembered the login for this system When the program is restarted the User and Password fields are already filled out Silent Login You have the option that the Meinberg Device Man ager does not ask for a user name and pass...

Page 37: ... of operation of Pulses OCXO SQ MQ HQ DHQ better than 50 nsec better than 2 µsec during the first 20 minutes of operation Frequency 10 MHz TTL level into 50 Ohm Outputs 1 MHz TTL level 100 kHz TTL level Frequency Synthesizer 1 8 Hz up to 10 MHz Accuracy of base accuracy depends on system accuracy Synthesizer 1 8 Hz to 10 kHz Phase syncron with pulse output P_SEC 10 kHz to 10 MHz frequency deviatio...

Page 38: ... Receiver GPS180 Receiver 12 channel C A code receiver with external antenna converter unit Antenna antenna converter unit with remote power supply Cable length max 300 m RG58 coax cable Antenna Connector BNC female Power Supply 15 V DC continuous short circuit protection automatic recovery for Antenna isolation voltage 1000 VDC provided via antenna cable GNS UC Receiver GNS181 UC Type of receiver...

Page 39: ...ES IPv4 IPv6 IEEE 1588v2 Default Profile NTPv3 NTPv4 IEEE C 37 238 2011 Power Profile PTPv1 PTPv2 IEEE C 37 238 2017 Power Profile IEC 62439 3 PRP IEC IEEE 61850 9 3 Power Utility Profile DHCP DHCPv6 Enterprise Profile DSCP ITU T G 8265 1 ITU T G 8275 1 ITU T G 8275 2 Telecom Profile IEEE 802 1q VLAN filtering tagging SMPTE ST 2059 2 Broadcast Profile IEEE 802 1p QOS IEEE 802 1AS TSN AVB Profile S...

Page 40: ...10 Technical Appendix GPS Antenna Accessories 10 Technical Appendix GPS Antenna Accessories Physical Dimensions microSync Date 29th July 2021 37 ...

Page 41: ...dth 9 MHz Frequencies Mixed frequency 10 MHz IF frequency 35 4 MHz Connector N Norm female connector Form factor ABS plastic case for outdoor installation Protection class IP66 Humidity 95 Temperature range 40 C to 85 C 40 to 185 F Weight 1 6 kg 3 53 lbs incl mounting kit 38 Date 29th July 2021 microSync ...

Page 42: ...ther values can be found in the data sheet of the cable used 10 2 Antenna Short Circuit Only for assembly groups with front display In case of an antenna line short circuit the following message appears in the display ANTENNA SHORT CIRCUIT DISCONNECT POWER If this message appears the clock has to be disconnected from the mains and the defect eliminated After that the clock can be powered up again ...

Page 43: ...ipped with two type N female connectors It has no dedicated input output polarity or prefered mounting orientation Phoenix CN UB 280DC BB Features High RF Performance Multiple Strike Capability 20 kA Surge Protection Bi directional Protection Mounting type Connection specific intermediate plugging Type Attachment plug Direction of action Line Shield Earth Ground Maximum continuous operating voltag...

Page 44: ...typ 1 5 pF asymmetrical shield typ 1 5 pF Surge current resistance conductor ground C1 1 kV 500 A C2 10 kV 5 kA C3 100 A D1 2 5 kA Ambient temperature operation 40 C 80 C Altitude 2000 m above sea level Degree of protection IP55 Housing material Nickel plated brass Color nickel Dimensions Height 25 mm Width 25 mm Depth 67 mm Connection data N Connector 50 Ohm IN N Connector Buchse OUT N Connector ...

Page 45: ...10 3 1 MBG S PRO Physical Dimensions 67 11 15 8 25 13 4 10 3 2 Installation and Grounding 42 Date 29th July 2021 microSync ...

Page 46: ...um polybrominated biphenyls PBBs and polybrominated diphenyl ethers PBDEs Bis 2 ethylhexyl phthalat DEHP Benzylbutylphthalat BBP Dibutylphthalat DBP Diisobutylphthalat DIBP above the legal threshold WEEE status of the product This product is handled as a B2B Business to Busi ness category product In order to secure a WEEE compliant waste disposal it has to be returned to the manufacturer Any trans...

Page 47: ...en übereinstimmt to which this declaration relates is in conformity with the following standards and provisions of the directives RED Richtlinie ETSI EN 303 413 V1 1 1 2017 06 RED Directive 2014 53 EU EMV Richtlinie ETSI EN 301 489 1 V2 2 3 2019 11 EMC Directive ETSI EN 301 489 19 V2 1 1 2019 04 DIN EN 61000 6 2 2019 2014 30 EU DIN EN 61000 6 3 2007 A1 2011 DIN EN 55032 2015 DIN EN 55024 2010 A1 2...

Reviews: