11.8.20.12 CPE-4020 Configuration via Web Interface
If the CPE-4020 operates in an IMS system, the output configuration can easily be done via the web interface
then.
With the "Common" tab the time zone with the corresponding offset can be selected.
Configuration: CPE-4020
In the "IO Config" menu you can select the following values for the output connectors:
Common:
Time zone with the corresponding UTC offset value
Synthesizer:
Frequency Synthesizer range 1 Hz - 10 MHz
IRIG Code:
Generated IRIG output codes (B002+B122 ...)
Serial:
Serial connection parameters
Prog. Out:
Programmable outputs Prog. Out 1 and Prog. Out 2
Figure: Serial connection parameter settings
The following programmable pulse outputs can be selected:
Idle
(not in use)
Timer
(3 switching-times On - Off)
Single Shot
(pulse length and start time)
Cyclic Pulse
(pulse length and cycle time)
Pulse Per Second
(pulse length)
Pulse Per Minute
(pulse length)
Pulse Per Hour
(pulse length)
DCF77 Marks
(timeout)
Position OK
(position determined)
Time Sync
(clock synchronized)
All Sync
(position determined and clock synchronized)
DCLS Time Code
Synthesizer Frequency
128
Date: 27th May 2021
IMS - LANTIME M4000