11 Technical Appendix
11.8.24.1 Error Relay
The illustration on the right shows the two switching states of an error relay.
Technical specification
Switching voltage max.:
220 V DC
250 V AC
Switching current max.:
2 A
Switching load max.:
60 W DC
62.5 VA AC
FCC surge breakdown voltage
1,500 V
between contacts and coil
Max. operating speed (at rated load)
60 cpm
Switching current UL/CSA:
0.3 A
125 V AC
0.3 A
110 V DC
1 A
30 V DC
Response Time:
ca. 3 ms
Normal Operation Mode
CO - NO connected
Normal Operation:
Error Mode
CO - NC connected
Error:
WARNING!
This equipment is operated at a hazardous voltage.
Danger to life due to electrical shock!
- Never work with open terminals and plugs while the power is on!
- When working on the connectors of the error relay cable,
always remove both sides of the cable from the respective devices!
Dangerous voltages can occur at the terminal of the fault signal relay!
Work on the terminal of the fault signal relay must never be carried
out with the signal voltage present!
-
IMS - LANTIME M4000
Date: 27th May 2021
145