SIM77 - amplitude-modulated time signal
The amplitude-modulated time signal is compatible
with the DCF77 signal, transmitted by the German
long-wave transmitter. The SIM77 signal is provided
via four DC insulated BNC sockets.
Note:
Important configuration parameters must be observed
when using the BPE-1060 module in an IMS system.
In the Web Interface, in the menu "Clock
→
Pro-
grammable pulse outputs
→
Prog. Out 1", the mode
must be set to
DCF77 Marks
. In the "Signal" drop-
down box, select
Normal
(see figure right).
The local time zone must be selected in the menu "Clock
→
Time Zone
→
Time Zone for External Outputs".
If the corresponding time zone is not available in this drop-down box, the time zone can be added manu-
ally in the menu "System
→
Display
→
Edit time zone table".
78
Date: 21st August 2019
IMS-M4000