Connector type:
5-pol. DFK
Pin assignment:
1: N/-
2: not connected
3: PE (Protective Earth)
4: not connected
5: L/+
Input parameter
——————————————————————————
Nominal voltage range:
U
N
=
100-240 V
∼
100-200 V
Max. voltage Range:
U
N
=
90-265 V
∼
90-250 V
Nominal current:
I
N
=
1.0 A
∼
0.6 A
Nominal frequency range:
f
N
=
50-60Hz
Max. frequency range:
f
max
=
47-63Hz
Output parameter
——————————————————————————
Maximum power:
P
max
=
50 W
Max. heat emission:
E
therm
=
180.00 kJ/h (170.61 BTU/h)
N/-
L/+
AD10
PWR
Power
U
= 100 V - 240 V
N
U
= 90 V - 265 V
max
I
= 1.0A
N
f
= 50 - 60Hz
N
U
= 100 V - 200 V
N
U
= 90 V - 250 V
max
I
= 0.6A
N
2
3
4
5
1
WARNING!
This equipment is operated at a hazardous voltage.
Danger to life due to electrical shock!
- Only qualified personnel (electricians) may connect the device.
- Never work with open terminals and plugs while the power is on.
- All connectors must be protected against touching live parts with
a suitable plug housing!
- Note: Always ensure safe wiring!
- Important: The device must be connected to a proper grounding (PE).
20
Date: 16th February 2021
LANTIME
Summary of Contents for LANTIME M300/MRS/AD10-AD10
Page 2: ......