9 LTOS7 Management and Monitoring
SNMP Trap Name:
mbgLtNgTrapNTPClientAlarm
OID:
.1.3.6.1.4.1.5597.30.3.0.15
Severity:
Error
Short explanation:
trap to be sent when an NTP Client Monitoring alarm occurs,
e.g. when a monitored client is not reachable
Reference to other chapters:
check the network configuration in
Cleared By:
-
SNMP Trap Name:
mbgLtNgTrapPowerSupplyUp
OID:
.1.3.6.1.4.1.5597.30.3.0.16
Severity:
Info
Short explanation:
trap to be sent when a power supply returned to a healthy state
Reference to other chapters:
no further information
Cleared By:
-
SNMP Trap Name:
mbgLtNgTrapNetworkDown
OID:
.1.3.6.1.4.1.5597.30.3.0.17
Severity:
Critical
Short explanation:
trap to be sent when a monitored network port is down
Reference to other chapters:
Cleared By:
mbgLtNgTrapNetworkUp
SNMP Trap Name:
mbgLtNgTrapNetworkUp
OID:
.1.3.6.1.4.1.5597.30.3.0.18
Severity:
Clearing event
Short explanation:
trap to be sent when a monitored network port is up
Reference to other chapters:
no further information
Cleared By:
-
SNMP Trap Name:
mbgLtNgTrapSecondaryRecNotRespp
OID:
.1.3.6.1.4.1.5597.30.3.0.19
Severity:
Warning or critical
Short explanation:
trap to be sent when secondary receiver is not responding
Reference to other chapters:
Cleared By:
mbgLtNgTrapSecondaryRecSync
SNMP Trap Name:
mbgLtNgTrapXmrLimitExceeded
OID:
.1.3.6.1.4.1.5597.30.3.0.30
Severity:
Warning
Short explanation:
trap to be sent when a reference offset exceeds the configured limit
Reference to other chapters:
Cleared By:
-
SNMP Trap Name:
mbgLtNgTrapXmrRefDisconnect
OID:
.1.3.6.1.4.1.5597.30.3.0.31
Severity:
Critical
Short explanation:
trap to be sent when a reference signal has been lost
Reference to other chapters:
Cleared By:
mbgLtNgTrapXmrRefReconnect
LANTIME CPU Expansion Shelf