SNMP Trap Name:
mbgLtNgTrapXheRubError
OID:
.1.3.6.1.4.1.5597.30.3.0.62
Severity:
Error
Short explanation:
trap to be sent when external rubidium announces error
Reference to other chapters:
no further information
Cleared By:
-
SNMP Trap Name:
mbgLtNgTrapPowerConsumptionExceeded
OID:
.1.3.6.1.4.1.5597.30.3.0.63
Severity:
Warning
Short explanation:
trap to be sent when device consumes too much power
Reference to other chapters:
no further information
Cleared By:
mbgLtNgTrapPowerConsumptionOk
SNMP Trap Name:
mbgLtNgTrapPowerConsumptionOk
OID:
.1.3.6.1.4.1.5597.30.3.0.64
Severity:
Info
Short explanation:
trap to be sent when device has got enough power
Reference to other chapters:
no further information
Cleared By:
-
SNMP Trap Name:
mbgLtNgTrapPowerRedundancyNotAvail
OID:
.1.3.6.1.4.1.5597.30.3.0.65
Severity:
Warning
Short explanation:
trap to be sent when there currently is no power supply backup avail
Reference to other chapters:
no further information
Cleared By:
mbgLtNgTrapPowerRedundancyAvail
SNMP Trap Name:
mbgLtNgTrapPowerRedundancyAvail
OID:
.1.3.6.1.4.1.5597.30.3.0.66
Severity:
Info
Short explanation:
trap to be sent when there is at least one power supply as backup
Reference to other chapters:
no further information
Cleared By:
-
SNMP Trap Name:
mbgLtNgTrapTrustedSourceError
OID:
.1.3.6.1.4.1.5597.30.3.0.67
Severity:
Warning
Short explanation:
trap to be sent when a XMR source’s time deviation exceeds
a configured limit
Reference to other chapters:
no further information
Cleared By:
mbgLtNgTrapTrustedSourceOk
SNMP Trap Name:
mbgLtNgTrapTrustedSourceOk
OID:
.1.3.6.1.4.1.5597.30.3.0.68
Severity:
Clearing Event
Short explanation:
trap to be sent when a XMR source’s time deviation returns to
its configured bounds
Reference to other chapters:
no further information
Cleared By:
-
160
Date: 2nd July 2020
LANTIME CPU Expansion Shelf
Summary of Contents for LCES
Page 2: ......