10 Troubleshooting and Alarming
Antenna Short Circuit
/
Short circuit at the antenna connection.
•
Disconnect the antenna cable from the LANTIME
antenna connector.
•
Perform a powercycle of the device
•
If the LANTIME does not show the error mes-
sage after the start-up, connect the antenna
again. Otherwise contact the Meinberg Tech-
Support and provide a LANTIME diagnostic file.
GPS Warm Boot
/
In warm boot mode, the GPS reference clock performs
the position determination. To complete this process
successfully, at least 4 satellites should be received.
After successful position determination, the position
will be stored in the battery-buffered memory of the
clock. Thus the position determination does not to be
carried out again after a restart.
•
If the LANTIME can not complete the GPS warm
boot process, check the number of "good satel-
lites" that can be viewed in the web interface:
"Clock
→
GPS (GNSS Clock
→
Receiver Infor-
mation
→
Number of good satellites".
•
If the number of good satellites is permanently
below 4 and the LANTIME can not complete the
position determination, then refer to the trou-
bleshooting case for "CLK Not Sync".
•
Contact your Meinberg TechSupport and provide
a LANTIME diagnostic file, if you need further
assistance at solving the problem.
GPS Cold Boot
/
In GPS Cold Boot mode, the GPS reference clock tries
to download the GPS almanac, which contains the
satellite track data for all satellites. To complete this
process, at least 1 satellite should be received. The
process takes at least 12 minutes. After the cold boot
is completed, the clock automatically switches to the
GPS warm boot to determine the position.
The GPS almanac is stored in the battery-buffered
memory of the clock.
•
If the LANTIME can not complete the GPS Cold
Boot operation after more than 30 minutes, check
the number of "good satellites" in the web inter-
face: "Clock
→
GPS (GNSS Clock
→
Receiver
Information
→
Number of good satellites".
•
If the number of good satellites is 0, then refer
to the troubleshooting case for "CLK Not Sync".
•
Contact your Meinberg TechSupport and provide
a LANTIME diagnostic file, if you need further
assistance at solving the problem.
LANTIME CPU Expansion Shelf
Date: 2nd July 2020
165
Summary of Contents for LCES
Page 2: ......