9.1.3.6 Notification Events
The "Notification Events" submenu provides an overview of all system events that may occur during LANTIME
operation. The checkboxes can be used to configure external alarms for each event. The following information
channels are available:
EMAIL:
Sends an e-mail based on the e-mail configuration (see chapter "E-mail Information")
SNMP:
Sends an SNMP Trap to the configured SNMP Trap (see chapter "SNMP Trap Receivers")
DISP:
Shows the notifications on the configured network displays
(see chapter "VP100/NET Display Information")
USER:
Activates the user-defined script (see chapter "Notifications")
ALED:
When the event occurs, the alarm LED of the LANTIME will light up
RELAY:
When the event occurs, the error relay at the LANTIME is set to ERROR
(see chapter "Error Relays")
1) Information; 2) Alarm; 3) Last change
Automatic Event Repeat:
An interval can be configured, with which notifications are sent again.
Max. Number of Repetitions:
The number of repetitions can be limited by this parameter.