9 LTOS7 Management and Monitoring
Event
Severity Levels (according to
X.733)
Description
SHS Time Limit Warning
Warning or Critical
The set threshold for an SHS
warning has been exceeded
SHS Time Limit Error
Critical
The set threshold for an SHS er-
ror has been exceeded ->
Power Supply Failure
Critical
Error detected on a power supply
->
Power Supply OK
Info event
Power supply ready for operation
Sync Monitor
Warning
Sync Monitor limits were ex-
ceeded
XMR Limit Exceeded
Warning
Set MRS limits have been ex-
ceeded ->
XMR Reference Disconnected
Critical
A configured MRS time source is
no longer available ->
XMR Reference Detected
Info or Warning
A configured MRS time source is
available
XMR Reference Changed
Info or Warning
The
active
MRS
source
has
changed
Network Link Down
Critical
No network connection on one of
the LAN ports ->
Network Link Up
Clearing event
Network connection detected on
the LAN port
PTP Link Down
Critical
No network connection on the
PTP network port
PTP Link Up
Clearing event
Network connection detected on
the PTP network port
PTP State Changed
Info or Warning
The
current
PTP
status
has
changed
Table: All Notification Events
LANTIME CPU Expansion Shelf
Date: 2nd July 2020
59
Summary of Contents for LCES
Page 2: ......