10 Troubleshooting and Alarming
10.2 Ref. Clock Messages
Error and System message / Explanation
CLK Not Responding
/
The LANTIME can no longer communicate with its
internal reference clock.
Troubleshooting / Additional information
•
Contact your Meinberg TechSupport and provide
a LANTIME diagnostic file.
CLK Not Sync
/
Performance and system ressources
issue of the NTP
LANTIME with GNSS reference clock
(GPS/GLN/GNS):
•
Check the antenna position:
•
If
the
GPS
reference
clock
is
connected
to
a
GPS
antenna
distributor
GPSAV4
(https://www.meinbergglobal.com/english/products/gps-
antenna-distributor.htm), make sure that the
"Clock 1" port of the GPSAV4 is attached , since
the GPSAV4 and the antenna are supplied by
power via this port.
LANTIME with a longwave receiver
(DCF77-PZF/WWVB/MSF/JJY):
•
Check the antenna position
LANTIME with TCR reference clock (IRIG):
•
Check whether the timecode input port at the
back of the LANTIME is correctly connected to
an IRIG source.
In the Web interface, check
whether the correct IRIG input code has been
configured (Clock
→
IRIG Settings
→
Input
Timecode). The input timecode is the IRIG code
provided to the LANTIME by the IRIG source.
•
Contact your Meinberg TechSupport and provide
a LANTIME diagnostic file, if you need further
assistance at solving the problem.