10.4 Miscellaneous Messages
Error and System message / Explanation
Fan Failure
/
The LANTIME has detected a fault on a fan module,
or a fan module has been removed during system op-
eration.
Troubleshooting / Additional information
•
If the fan module has not been intentionally re-
moved, contact the Meinberg TechSupport and
provide a LANTIME diagnostic file.
IMS Error
/
Either the LANTIME has detected an error on an IMS
module or an IMS module has been plugged out of the
LANTIME IMS system during the operation.
Troubleshooting / Additional information
•
If the IMS module has not been intentionally re-
moved, contact the Meinberg TechSupport and
provide a LANTIME diagnostic file.
CPU No Response
(This error message can only ap-
pear on a display) /
The display does not receive any information from the
installed LANTIME CPU unit.
Troubleshooting / Additional information
•
Check whether the LANTIME is still available
over the network (try to ping, SSH, HTTP /
HTTPS)
•
Does a power cycle solve this problem?
•
If the LANTIME is still accessible via HTTP /
HTTPS, please download a diagnostic file via
the web interface and send it to the Meinberg
TechSupport. If no connection to the LANTIME
is possible, contact the Meinberg TechSupport
with the serial number of your LANTIME.
Certificate Expired
/
LANTIME generates this warning 60 days, 30 days,
and 15 days before the end period of the installed SSL
certificate for HTTPS service.
Troubleshooting / Additional information
•
Check the validity of the installed SSL certifi-
cate via the Web Interface: "Security
→
HTTPS
Certificate
→
Show SSL Certificate".
•
Upload a new SSL certificate using the LAN-
TIME Web Interface in the Security Page dia-
logue.: "Security
→
HTTPS Certificate
→
Up-
load SSL Certificate".
•
Contact your Meinberg TechSupport and provide
a LANTIME diagnostic file, if you need further
assistance at solving the problem.