GB
83
Checking the compressor and scope of delivery
Checking the compressor and scope of delivery
1. Take the compressor carefully out of its packaging.
2.
Check whether the delivery is complete (see
Fig. A
).
3. Check whether the compressor or components have any damage. If this is the case, do not
use the compressor. Please contact the manufacturer using the service address given on
the back of the user manual.
4. If possible, retain the packaging until the end of the warranty period.
Operation
NOTICE!
Risk of damage!
The compressor is not suitable for continuous operation. Continuous
operation for too long or overloading the compressor causes overheating.
It could get damaged.
–
Operate the compressor for no longer than 10 minutes at a time.
–
Operate the compressor at the rated input power for a maximum of 15%
of this time (1.5 minutes). During the rest of the period, the compressor
can cool down again.
–
Turn the compressor off after 10 minutes of continuous operation and
allow it to cool down for at least 10 minutes.
–
Do not exceed the allowable power range of the compressor.
Do not inflate any lorry, tractor or other large tyres.
NOTICE!
Risk of damage!
Operating the compressor with long supply lines, extensions or cable drums
can cause a voltage drop and prevent the motor starting. An undersized
compressed air system can reduce the efficiency of the compressor.
–
If possible, do not use long supply lines, extensions or cable drums.
Summary of Contents for 5404300
Page 2: ...Dok Rev Nr 194792_01_20170330 2 ...
Page 3: ...3 Übersicht A 1 11 2 3 4 6 7 8 9 10 12 13 14 15 16 17 18 5 20 19 ...
Page 48: ...CZ 48 ...
Page 72: ...F 72 ...
Page 138: ...PL 138 ...
Page 159: ...159 Konformitätserklärung Konformitätserklärung ...