background image

 

 

4

 

5. Operating Manual 

 
5.1 On/Off 

 

  Press the ON/OFF button to activate or deactivate the thermostat. 

  The word "ON" or "OFF" will appear in the display. 

 

 

5.2 Set temperature   

 

  Press the SET buttons (+) or (-) - the temperature will flash. 

  Adjust the set temperature using the (+) or (-) buttons. 

 

5.3 Selecting modes 

 

Press the MODE button to switch between the four modes:  

 Cool 

 Heat 

 Cool/heat (auto-change over), 

 Fan only. 

  Emergency heat selectable in heat mode in Heat Pump type (only). 

ƒ

 

Press and hold the MODE button (5 seconds) to activate Emergency 
heat (Heat Elements) and the compressor will be OFF.  
This selection is for cold days when the outside temperature is very low and the 
Heat Pump is active in heat. 

ƒ

 

To return back to Heat mode press and hold the MODE button again (only in Heat mode).  

 

5.4 Fan/Auto Fan function  

 

  Press the FAN button to select AUTO FAN. 

  Press the FAN button again to cancel.  

 
In AUTO FAN the fan will only run when calling for heat or cool. 
 
 

6. RT03-HC-1S - Hand Held Remote Control - Option

 

 

6.1 General 

 

This is an Infrared Remote Control Unit, which means it must be pointed at the thermostat (or 

extra receiver) to operate.   

Every time you change a parameter in the Remote Control, you must send it to the thermostat 

by pressing the "ON/SEND". 

 
6.2 RT03-HC-1S - Operating Manual 

 

  Press the ON/SEND to activate the air conditioner and/or updating information.  

 

 
Fan Mode: 

 

  Press the FAN button to change between: FAN ON ( ) or AUTO FAN (A). 

  Press the ON/SEND button to send information to thermostat. 

 

Mode: 

 

  Press the MODE button to change between:  

COOL, HEAT, AUTO CHANGE and FAN ONLY. 

  Press the ON/SEND button to send information to thermostat. 

 

Temperature Set Point: 

 

  Adjust the desired temperature using the (+) or (-) buttons. 

  Press ON/SEND button to send information to thermostat.  

 

Summary of Contents for ETN-24-SUPER-SI Series

Page 1: ...ternal sensor option RS01 for remote temperature sensing 1 required RS01 for averaging temperature with thermostat 4 required RS02 for averaging temperature with thermostat 2 required RS02 has two the...

Page 2: ...S1 HEAT PUMP HEAT 3 W3 S2 HEAT 1 W1 S3 HEAT 2 W2 S4 External sensor S5 External sensor S6 COMP 2 Y2 S7 FAN S8 COMP 1 Y1 IMPORTANT Before making any changes in the DIP switch disconnect electricity in...

Page 3: ...6 pins Each pin can be ON or OFF In this example picture pins 1 6 ON and pins 2 3 4 5 OFF 4 3 External sensor connection option Important The external sensor must be Meitav Tec type Table 4 3 N TC Se...

Page 4: ...n Auto Fan function Press the FAN button to select AUTO FAN Press the FAN button again to cancel In AUTO FAN the fan will only run when calling for heat or cool 6 RT03 HC 1S Hand Held Remote Control O...

Page 5: ...he hours using the or buttons Press the SELECT button the minutes will flash Adjust the minutes using the or buttons Stop Time Press the SELECT button PROGRAM STOP flashing will appear on display Pres...

Page 6: ...on display Adjust set offset using the and buttons range 6 C 6 C default 0 C Set point for cool in economy mode Press the ON button again AUX and COOL will appear on display Adjust set limit for cool...

Page 7: ...OFF Option B The thermostat will change the set point Economy mode To change this options in the thermostat please refer to the dip switch explanation When the thermostat is OFF the window contact is...

Reviews: