background image

MEITRACK MT90A User Guide                                                                                                                   

 

Copyright ©  2014 Meitrack Group All rights reserved.                                             

                                                 

      - 13 -

 

7.5

 

Time Zone 

  B35 

The command is used to modify the SMS report to display the correct local time zone. Default value: Beijing time, GMT480.   

To change the time zone, follow the following instructions: 

 

SMS text: 

0000,B35,480 

Send the text to the embedded SIM card phone number. 

 

The MT90A automatically replies to the SMS: IMEI,B35,OK. It indicates that the time zone is set successfully. 

Note: The time zone is in unit of minutes. The default time zone on the tracker is GMT 8 (480 minutes), and the time zone of 

SMS reports is different from that of GPRS data packets. The GPS Log time zone is GMT 8. 

When 

SMS minute

 is 

0

, the time zone is 

GMT 0

 (default time zone). 

When 

SMS  minute

  is  a  value  ranging  from  -32768  to  32767,  set  different  time  zones.  Set  the  China  time  zone  value  to 

480

 

(default value). 

Example: 0000,B35,480 

Reponding: 353358017784062,B35,OK (The time zone is set to Beijing time successfully.) 

The digit is your MT90A’s IMEI number. 

7.6

 

Man Down Alarm – A29 

The command is used to enable the man down alarm function. An alarm will be generated in case of falling. 

SMS text: 

0000,A29,

Switch

,

Time

,

Grade

 

Responding: 

IMEI

,A29,OK 

Note: 

1.

 

Switch

:  indicates  the  man  down  alarm  detection  switch.  When  the  parameter  value  is 

1

,  enable  the  man  down  alarm 

function. When the parameter value is 

0

, disable the man down alarm function. 

2.

 

Time

: indicates the buzzing and vibration time after falling.  In this period, you can press any button to clear  the alarm, 

and  thus  avoid  inaccurate  alarm  information.  After  the  period,  an  alarm  will  be  generated  or  a  call  will  be  made.  The 

parameter unit is second. Value range: 0–255. Default value: 10. 

3.

 

Grade

: indicates the man down alarm grade. The parameter value ranges from 0 to 3. The default value is 

1

. The smaller 

the value is, the high probability an alarm will be generated. 

If an authorized phone number was set by using command A71, the phone number will receive SMSs and calls by default when 

a man down alarm is generated. 

For details about SMS commands, see the 

MEITRACK SMS Protocol

8

 

Configured on a Computer 

This section describes how to use Meitrack Manager to configure the MT90A on a computer. 

Procedure: 

1.

 

Install the USB driver and  Meitrack Manager. 

2.

 

Connect the MT90A to a PC with a USB cable. 

Summary of Contents for MT90A

Page 1: ...MEITRACK MT90A User Guide MEITRACK MT90A User Guide...

Page 2: ...Group All rights reserved 2 Change History File Name MEITRACK MT90A User Guide Created By Renny Lee Project MT90A Creation Date Update Date 2011 05 16 2014 09 02 Subproject User Guide Total Pages 15...

Page 3: ...y Alarm 4 3 1 3 Other Functions 4 3 2 Specifications 5 4 MT90A and Accessories 5 5 About the MT90A 6 5 1 Appearance 6 5 2 Indicator 7 6 First Use 8 7 Quick Operation Command 9 7 1 Real time Location T...

Page 4: ...onomic losses personal injuries and loss of assets and property caused by the use inability or illegality to use the product or documentation 2 Product Overview The MT90A a personal tracking device is...

Page 5: ...ption 60 mA standby current and 5 mA deep sleep Operating temperature 20 C to 55 C Humidity 5 to 95 Working hour 240 hours in power saving mode and 14 hours in normal mode Indicator 2 indicators showi...

Page 6: ...so dial three authorized phone numbers in turn It will stop dialing when one phone number answers Meanwhile the MT90A will send an SMS to the authorized phone number and send a GPRS message to the ser...

Page 7: ...ault GPRS message interval is 10 minutes Press and hold down the button for 2s again when the buzzer sounds BI twice the GPRS function will be disabled automatically Note To avoid misoperations you ca...

Page 8: ...ote Ensure that the SIM card password lock is closed and the SIM card has sufficient balance and has subscribed the call ID service If you want to use the GPRS function learn about the SIM card GPRS c...

Page 9: ...ter into a power outlet Note Incorrect connection may cause serious damages to the device Any damage caused by misuse is not covered in the warranty Attach a lanyard Slide the lanyard through the slot...

Page 10: ...e V The GPS is invalid A Valid V Invalid 16 Indicates the GSM signal strength Value 1 32 The larger the value is the stronger the signal is If the value is greater than 12 GPRS reaches the normal leve...

Page 11: ...ntains a maximum of 16 bytes If no function number is set leave Function number blank default value Function number 1 Set the phone number to the SOS number When you dial the tracker the tracker repli...

Page 12: ...ers send 0000 A72 7 4 Smart Sleep A73 This command is used to enable the sleep mode function prolonging standby time to 240 hours In this mode the recorder scheduled tracking and location tracking fun...

Page 13: ...d to enable the man down alarm function An alarm will be generated in case of falling SMS text 0000 A29 Switch Time Grade Responding IMEI A29 OK Note 1 Switch indicates the man down alarm detection sw...

Page 14: ...User name IMEI number Password 0000 default You can perform the following operations on the GPS platform Query a location at certain time Query the trace Add favorites View various reports For more i...

Page 15: ...ndicates that this product and its accessories such as chargers batteries and the USB cable cannot be disposed of with other household wastes when they reach the end of their life If batteries are not...

Reviews: